BDF 200 AS
Operating instructions
Control panel with emergency stop
EN
AS-Interface parameter port:
P0 … P3: not used
Input module address:
0,
preset to address 0, can be
changed through AS-interface bus master
or hand-held programming device
Ambient conditions:
Ambient temperature:
−25 °C ... +65 °C
Storage and transport temperature:
−25 °C ... +85 °C
Climatic resistance:
to DIN EN 60068 Part 2 - 30
Protection class:
IP65
Protection class:
II
x
Resistance to vibration:
10 150 Hz (035 mm / 5 g)
Resistance to shock:
15 g / 11 ms
Overvoltage category:
III
Degree of pollution:
3
Rated impulse withstand voltage U
imp
:
800 V
Rated insulation voltage U
i
:
32 VDC
2.5 Safety classification emergency stop
Standards:
EN ISO 13849-1, IEC 61508
PL:
up to e
Control category:
up to 4
PFH-value:
≤ 1.4 x 10
-8
/h up to max
5,000 switching cycles/year
SIL:
up to 3
Service life:
20 years
3. Mounting
3.1 General mounting instructions
For the correct fixing of the BDF 200 AS control panel, the device is
provided with two mounting holes for M5 screws are provided Any
mounting position
Please observe the remarks of the standards EN ISO 12100,
EN 953 and EN 1088
3.2 Dimensions
All measurements in mm
8
5.5
209
27
50
M12
40
220
13.5
39
30
3.3 Mounting of the control panel
Remove the cover of the enclosure a and b (screws: Torx 10)
When opening the enclosure cover, please avoid damage
to the connecting cables
Caution!
Do not touch electrostatically loaded elements
Do not touch the printed circuit board
Use 2 x M5 cylindral screws ISO 4762 (DIN 912) for the assembly
When closing the enclosure cover, please observe that the
individual cables are not caught between the command
device and the contact element
After fitting, the cover screws must be tightened with a tightening
torque of 07 - 08 Nm
a
b
3.4 Inscription plates with fastening clips
The identification fields can be labelled with two-layer plastic inscription
fields (included in delivery) After that, they are fixed with the fastening
clips (included in delivery)