Operating instructions

Solenoid interlock

AZM190

EN

AZM190-E-EN

7. EU Declaration of conformity

Name of the component:

AZM190

Type:

See ordering code

Description of the component:

Interlocking device with electromagnetic interlock 

for safety functions (solenoid interlock)

Relevant Directives:

Machinery Directive

RoHS-Directive

2006/42/EC

2011/65/EU

Applied standards:

DIN EN 60947-5-1:2010,  

DIN EN ISO 14119:2014

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

The currently valid declaration of conformity can be  

downloaded from the internet at wwwschmersalnet

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Place and date of issue:

Wuppertal, February 25, 2016

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

KA Schmersal GmbH & Co KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: wwwschmersalcom

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives 

Summary of Contents for AZM190

Page 1: ...be exclusively used in accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as al...

Page 2: ...ave been eliminated Solenoid interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the risk of accident since the safety guard can be opened immediately on failure of the power supply or upon activation of the main switch The safety switchgears are classified according to ISO 14119 as type 2 interlocking devices Manual release for set up maintenan...

Page 3: ... vary depending on the application specific parameters hop dop and tcycle as well as the load If multiple safety components are wired in series the Performance Lev el to ISO 13849 1 will be reduced due to the restricted error detection under certain circumstances 3 Mounting 3 1 General mounting instructions Please observe the relevant requirements of the standards ISO 12100 EN 953 and ISO 14119 Th...

Page 4: ... the LED versions are not potential free In combination with these devices only sequential circuits can be used in which both channels are controlled with positive potential 4 2 Contact variants Contacts shown in a de energised condition and with the actuator inserted The contact configurations of the versions with or without LED are identical LED display YE 1 Safety guard closed GN 2 Safety guard...

Page 5: ...nd met 1 Fitting of the solenoid interlock and the actuator 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 5 2 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check for tight installation of the actuator and the switch 2 Remove particles of dust and soiling 3 Check cable entry and connectio...

Page 6: ...42279 Wuppertal The currently valid declaration of conformity can be downloaded from the internet at www schmersal net K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal February 25 2016 Authorised signature Phil...

Reviews: