AZM190
Operating instructions
Solenoid interlock
EN
2.4 Technical data
Standards:
IEC 60947-5-1; ISO 14119; BG-GS-ET-19
Enclosure:
glass-fibre reinforced thermoplastic
Actuator and locking bolt:
Galvanised steel / zinc die-cast
Holding force:
1950 N
Latching force:
20 N
Coding level according to ISO 14119:
low
Protection class:
IP67
- Ordering suffix N and T:
IP65
Contact material:
Silver
Contact type:
change-over contact with double break, or 2 NC
contacts, with galvanically separated contact bridges
Switching system:
A
IEC 60947-5-1; slow action,
NC contact with positive break
Connection:
screw terminals
Cable type:
solid and stranded wire
Cable section:
05 … 25 mm², (max 15 mm²
with conductor ferrules);
- Components with 4 contacts:
05 … 15 mm² (incl conductor ferrules)
Cable entry:
2x M20
Rated impulse withstand voltage U
imp
:
4 kV;
- Device with 4 contacts or 3 contacts with LED:
1
5 kV
Rated insulation voltage U
i
:
250 V;
- Device with 4 contacts or 3 contacts with LED:
60 VAC
Thermal test current I
the
:
4 A
Utilisation category:
AC-15, DC-13
Rated operating current/voltage I
e
/U
e
:
4 A / 230 VAC;
4 A / 24 VDC;
- Device with 4 contacts or 3 contacts with LED:
AC-15: 4 A / 60 VAC
Max fuse rating:
4 A gG D-fuse to IEC 60269-1
Required short-circuit current:
1000 A
Positive break travel:
2 × 3,5 mm
Positive break force:
20 N
Magnet:
100% ED
Rated control voltage U
s
:
24 VDC, 24 VAC 50/60 Hz,
48 VAC 50/60 Hz,
110 VAC 50/60 Hz,
230 VAC 50/60 Hz
Power consumption:
max 85 W
Actuating speed:
max 20 m/min
Actuating frequency:
max 1,200/h
Ambient temperature:
0 °C … +50 °C
Mechanical life:
1 × 10
6
operations
Listed 15 HA - Industrial Control Equipment - Enclosure
Type I - "Use Copper Wire Only" - "Use 60/75° Wire Only" -
Tightening Torque 08 Nm The hub shall be connected to
the conduit before it is connected to the enclosure
2.5 Safety classification
Standards:
ISO 13849-1
Envisaged structure:
- Basically:
applicable up to cat 1 / PL c
- With 2-channel usage
applicable up to cat 3 / PL d
and fault exclusion mechanism:
with suitable logic unit
B
10d
NC contact:
2,000,000
B
10d
NO contact at 10% ohmic contact load:
1,000,000
Service life:
20 years
MTTF
B
d x
x
h
s/h
3600
d
10d
op
op
op
n
0,1 x n
op
t
cycle
(Determined values can vary depending on the application-specific
parameters h
op
, d
op
and t
cycle
as well as the load)
If multiple safety components are wired in series, the Performance Lev-
el to ISO 13849-1 will be reduced due to the restricted error detection
under certain circumstances
3. Mounting
3.1 General mounting instructions
Please observe the relevant requirements of the standards
ISO 12100, EN 953 and ISO 14119
Three mounting holes are provided for fixing the enclosure The sole-
noid interlock is double insulated The use of an earth wire is not au-
thorised The solenoid interlock must not be used as an end stop Any
mounting position The components however must be mounted so that
the opening of the actuating head is protected against the penetration
of dirt (eg sand, dust, chips)
In case of painting activities, the components must be covered In case
of horizontal mounting, the cover plate (Fig 1) situated at the back of
the actuating head must be removed
Assembly with mounting plate MP 190 and actuator AZM 190-B3 see
fig 2 (Internal mounting of the interlock and mounting plate with door
hinge on right-hand side)
Fig. 1
Fig. 2
Where the door hinge is on the left, the mounting plate
along with the interlock is rotated through 180°
Alternative mounting plates that can be used in
combination with actuator AZM190-B3V especially for
attaching aluminium profiles, see www.schmersal.net.
MP190-V
For internal mounting with right-hinged door
MP190-VD
For internal mounting with left-hinged door
By default, the key hole is at the top If another actuating direction is
desired, the four screws of the actuating head must be loosened Turn
the actuating head in the desired direction and retighten the screws
(tightening torque 05 Nm) The default screws installed in the actuating
head can be replaced with the supplied tamperproof screws
For power-to-unlock devices the actuator must be inserted
when the actuating head is turned Any non-observance
of this prescription could result in the components being
damaged
The safety component and the actuator must be permanently
fitted to the safety guards and protected against displacement
by suitable measures (such as tamperproof screws, gluing,
drilling, or pinning)
When used in ambient temperatures > 40°C, the solenoid
interlock must be protected against contact with inflammable
materials or inadvertent personal contact