6  Set-up and maintenance

6.1  Functional testing

The safety function of the safety components must be tested. The 

following conditions must be previously checked and met:

1. Check the switch enclosure for damage. 

2. Check the free movement of the actuating element

3. Check the integrity of the cable entry and connections

6.2  Maintenance

A regular visual inspection and functional test, including the following 

steps, is recommended:

1. Check the free movement of the actuating element

2. Remove particles of dust and soiling

3 Check cable entry and connections

Damaged or defective components must be replaced.

7  Disassembly and disposal

7.1  Disassembly

The safety switchgear must be disassembled in a de-energised condi-

tion only.

7.2  Disposal

The safety switchgear must be disposed of in an appropriate manner in 

accordance with the national prescriptions and legislations.

AZM 170 B ST-AS .A. 

B-variant, power to lock (magnet-operated locking)

System condition

Magnet input

AS-i D Out: 0

AS-i power

Green LED

Authorized operation

Yellow LED

SaW code

Authorized operation

Parameter port

P0 - P1 - P2 - P3

Safety guard open

0

ON

-

0

0

0

0

0

0

1

1

Safety guard closed

0

ON

ON

SaW code

1

0

1

1

Safety guard locked

1

ON

ON

SaW code

1

1

1

1

AZM 170 BZ ST-AS .A.

 

BZ-variant, power to lock (magnet-operated locking)

System condition

Magnet input

AS-i D Out: 0

AS-i power

Green LED

Authorized operation

Yellow LED

SaW code

release

Parameter port

P0 - P1 - P2 - P3

Safety guard open

0

ON

-

0

0

0

0

0

0

1

1

Safety guard closed

0

ON

-

0

0

HC 2*

1

0

1

1

Safety guard locked

1

ON

ON

SaW code

1

1

1

1

HC 2*. Half-code 2 (AS-i SaW bit 2,3)

AZM 170 B ST-AS .. 

 

B-variant, power to unlock (spring-operated locking

System condition

Magnet input

AS-i D Out: 0

AS-i power

LED green

Authorized operation

LED yellow

SaW code

release

Parameter port

P0 - P1 - P2 - P3

Safety guard open

1

ON

-

0

0

0

0

0

0

1

1

Safety guard closed

1

ON

ON

SaW code

1

0

1

1

Safety guard locked

0

ON

ON

SaW code

1

1

1

1

AZM 170 BZ ST-AS .. 

 

BZ-variant, power to unlock (spring-operated locking)

System condition

Magnet input

AS-i D Out: 0

AS-i power

LED green

Authorized operation 

LED yellow

SaW code

release

Parameter port

P0 - P1 - P2 - P3

Safety guard open

1

ON

-

0

0

0

0

0

0

1

1

Safety guard closed

1

ON

-

0

0

HC 2*

1

0

1

1

Safety guard locked

0

ON

ON

SaW code

1

1

1

1

HC 2*. Half-code 2 (AS-i SaW bit 2,3)

Reviews: