6 Set-up and maintenance
6.1 Functional testing
The safety function of the safety components must be tested. The
following conditions must be previously checked and met:
1. Check the switch enclosure for damage.
2. Check the free movement of the actuating element
3. Check the integrity of the cable entry and connections
6.2 Maintenance
A regular visual inspection and functional test, including the following
steps, is recommended:
1. Check the free movement of the actuating element
2. Remove particles of dust and soiling
3 Check cable entry and connections
Damaged or defective components must be replaced.
7 Disassembly and disposal
7.1 Disassembly
The safety switchgear must be disassembled in a de-energised condi-
tion only.
7.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.
AZM 170 B ST-AS .A.
B-variant, power to lock (magnet-operated locking)
System condition
Magnet input
AS-i D Out: 0
AS-i power
Green LED
Authorized operation
Yellow LED
SaW code
Authorized operation
Parameter port
P0 - P1 - P2 - P3
Safety guard open
0
ON
-
0
0
0
0
0
0
1
1
Safety guard closed
0
ON
ON
SaW code
1
0
1
1
Safety guard locked
1
ON
ON
SaW code
1
1
1
1
AZM 170 BZ ST-AS .A.
BZ-variant, power to lock (magnet-operated locking)
System condition
Magnet input
AS-i D Out: 0
AS-i power
Green LED
Authorized operation
Yellow LED
SaW code
release
Parameter port
P0 - P1 - P2 - P3
Safety guard open
0
ON
-
0
0
0
0
0
0
1
1
Safety guard closed
0
ON
-
0
0
HC 2*
1
0
1
1
Safety guard locked
1
ON
ON
SaW code
1
1
1
1
HC 2*. Half-code 2 (AS-i SaW bit 2,3)
AZM 170 B ST-AS ..
B-variant, power to unlock (spring-operated locking
System condition
Magnet input
AS-i D Out: 0
AS-i power
LED green
Authorized operation
LED yellow
SaW code
release
Parameter port
P0 - P1 - P2 - P3
Safety guard open
1
ON
-
0
0
0
0
0
0
1
1
Safety guard closed
1
ON
ON
SaW code
1
0
1
1
Safety guard locked
0
ON
ON
SaW code
1
1
1
1
AZM 170 BZ ST-AS ..
BZ-variant, power to unlock (spring-operated locking)
System condition
Magnet input
AS-i D Out: 0
AS-i power
LED green
Authorized operation
LED yellow
SaW code
release
Parameter port
P0 - P1 - P2 - P3
Safety guard open
1
ON
-
0
0
0
0
0
0
1
1
Safety guard closed
1
ON
-
0
0
HC 2*
1
0
1
1
Safety guard locked
0
ON
ON
SaW code
1
1
1
1
HC 2*. Half-code 2 (AS-i SaW bit 2,3)