background image

FR

Vous trouverez la version  

actuelle du mode d’emploi dans 

votre langue nationale officielle 

sur l’Internet,  

www.schmersal.net.

ES

Encontrará el manual de  

instrucciones actual en su  

idioma oficial de la UE en 

nuestra página de Internet  

www.schmersal.net.

NL

U vindt de huidige versie van de 

gebruikshandleiding in uw  

officiële landstaal op het Inter-

net, www.schmersal.net.

IT

Il manuale d‘istruzioni aggior-

nato nella vostra lingua (lingua 

ufficiale UE) è scaricabile in 

Internet all‘indirizzo  

www.schmersal.net.

JP

EU公用語で書かれた最新の取扱

説明書は,インターネッ

 

(www.schmersal.net) からダウ

ンロードできます。

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 4

Translation of the original operating instructions

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .3

4.2  Contact variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

7  Appendix

7.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

x.

00

/ v

.A

. /

 1

0.

20

10

 / 

 B

Z-

N

r. 

50

15

3-

13

V

90

/ T

ei

le

-N

r. 

11

40

08

3-

E

N

 / 

A

us

ga

be

 D

1

AZ 415-33ZPK

Operating instructions

Safety switch

EN

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure  the safe 

operation and disassembly of the safety switchgear. The operating inst-

ructions must be available in a legible condition and a complete version 

in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards to 

be complied with as well as other technical specifications for the selec-

tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution: 

Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning: 

Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the proper functionality of the entire machinery or plant.

The safety switchgear must be exclusively used in accordance with the 

versions listed below or for the applications authorised by the manufac-

turer. Detailed information regarding the range of applications can be 

found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-

tions manual, the country-specific installation standards as well as all 

prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is provi-

ded without liability and is subject to technical modifications.

If multiple safety components are wired in series, the Perfor-

mance Level to EN ISO 13849-1 will be reduced due to the 

restricted error detection under certain circumstances. The 

entire concept of the control system, in which the safety com-

ponent is integrated, must be validated to EN ISO 13849-2.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

Summary of Contents for AZ 415-33ZPK

Page 1: ...sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selec tion mounting and integrat...

Page 2: ...eleased and switch insert S2 actuated differentiated operating principle When the actuator is fully inserted the safety guard is not subject to any ejection force When the safety guard is opened the NC contacts are positively ope ned and the NO contacts are closed The user must evaluate and design the safety chain in accordance with the relevant standards and on the required safety level 2 4 Techn...

Page 3: ...wiring compartment Maximum tightening torque for the screws cover 0 6 0 1 Nm bottom cover 0 7 0 1 Nm The conductors of the connecting cables must not obstruct the movement of the switching lever 4 2 Contact variants Contacts are shown with safety guard closed 23 21 11 13 31 33 24 22 12 14 32 34 S2 S1 S3 Legend P actuated Q not actuated A Positive break NC contact 5 Set up and maintenance 5 1 Funct...

Page 4: ...ty K A Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal 11 May 2009 Authorised signature Heinz Schmersal Managing Director EC Declaration of conformity Translation of the original ...

Reviews: