schmersal AES 1337 Operating Instructions Manual Download Page 1

AES 1337

Operating instructions

Safety-monitoring module

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety-monitoring module. the 

operating instructions must be available in a legible condition and a 

complete version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety-monitoring module must be exclusively used in accordance 

with the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

To avoid EMC disturbances, the physical ambient and 

operational conditions at the place where the product is 

installed, must meet the provisions laid down in the paragraph 

"Electromagnetic Compatibility (EMC)" of DIN EN 60204-1.

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .3

5  Operating principle and settings

5.1  LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5.2  Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5.3  Notes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

8  Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

8.2 

Start configuration (with edge detection)

. . . . . . . . . . . . . . . . . . . . .5

8.3 

Sensor configuration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8.4 

Actuator configuration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

9  EU Declaration of conformity

x.000 / 1

1.2017 / v

.A.   -   101

171987-EN / E / 2017-1

1-08 / 

AE-Nr

. 8358

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Original

Summary of Contents for AES 1337

Page 1: ...nce with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description To avoid EMC disturbances the physical ambient and operational conditions at the place where the product is installed must meet the provisions laid down in the paragraph Electromagnetic Compatibility EMC o...

Page 2: ...a PFH value assessment also refer to chapter 2 5 Safety classification Control category 4 PL e to DIN EN ISO 13849 1 corresponds to SIL 3 to DIN EN 61508 2 SILCL 3 to DIN EN 62061 To determine the Performance Level PL of the entire safety function e g sensor logic actuator to DIN EN ISO 13849 1 an analysis of all relevant components is required 2 4 Technical data General data Standards IEC EN 6020...

Page 3: ...IN rail and push up until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D 100 x 22 5 x 121 mm 4 Electrical connection 4 1 General information for electrical connection As far as the electrical safety is concerned the protection against unintentional contact of the connected and therefore electrically interconnected apparatus and the insulation of the feed cable...

Page 4: ...lth however at least 1x year Damaged or defective components must be replaced 7 Disassembly and disposal 7 1 Disassembly The safety monitoring module must be disassembled in a de energised condition only Push up the bottom of the enclosure and hang out slightly tilted forwards 7 2 Disposal The safety monitoring module must be disposed of in an appropriate manner in accordance with the national pre...

Page 5: ...ossible Dual channel control of magnetic safety switches to EN 60947 5 3 Fig 7 Wire breakage and earth leakage in the control circuits are detected Cross wire shorts between the monitoring circuits are detected Category 4 PL e to DIN EN ISO 13849 1 possible S22 S21 S14 S13 S22 S21 S14 S13 S22 S14 S21 S13 Fig 5 Fig 6 Fig 7 The connection of magnetic safety switches to the AES 1337 safety monitoring...

Page 6: ...Zertifizierungsstelle Elektrotechnik Gustav Heinemann Ufer 130 50968 Köln ID n 0340 EC prototype test certificate ET 16102 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal November 8 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH ...

Reviews: