Summary of Contents for AES 1135

Page 1: ...he applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further tech...

Page 2: ...cture They include two safety relays with monitored positive action contacts The NO contacts of the relays which are wired in series build the enabling contacts 2 4 Technical data Standards EN 60204 1 EN 60947 5 3 EN ISO 13849 1 IEC 61508 BG GS ET 14 BG GS ET 20 Start conditions Automatic Feedback circuit available no Start up test AES 5 no AES 6 yes Pull in delay for automatic start adjustable 0 ...

Page 3: ...nd the LED flashes yellow Inputs S14 S22 Connect a safety switch with one NC and one NO contact or two safety switches with one contact each or an emergency stop button at input S14 S22 Safety switch with two NC contacts X1 For an operation with two NC contacts input X1 must be supplied with 24 VDC Outputs Enabling paths 13 14 NO contacts for safety functions Additional outputs Y1 Y2 AES 1135 1136...

Page 4: ...ED flashes yellow 0 5 Hz Enabling paths open LED flashes yellow 2 Hz Safety guard closed however no release possible causes incorrect operation only one contact actuated upon opening or voltage drop perform start up test In case of error messages the LED lights orange intermittently During these intermissions the LED flashes one up to seven times with short pulses Table error indications Indicatio...

Page 5: ...ctive Person authorized for the compilation of the technical documentation Ulrich Loss Möddinghofe 30 42279 Wuppertal Notified body which approved the full quality assurance system referred to in Appendix X 2006 42 EC TÜV Rheinland Industrie Service GmbH Alboinstraße 56 12103 Berlin ID n 0035 Place and date of issue Wuppertal October 7 2009 Authorised signature Heinz Schmersal Managing Director EC...

Page 6: ...H Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...