Schmalz VSi D Series Operating Instructions Manual Download Page 43

IO-Link Data Dictionary

VSi series

21.10.01.00097/03

20.04.2022

J. Schmalz GmbH
Johannes-Schmalz-Straße 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
www.schmalz.com
[email protected]

62

0x003E

1

SP2/FH2

2 bytes

V:   999 >= SP2 > rP2
       999 >= FH2 > FL2+Hy2
P:   9999 >= SP2 > rP2
       9999 >= FH2 > FL2+Hy2
VP: 8000 >= SP2 > rP2
       8000 >= FH2 >FL2+Hy2

rw

V: 550
P: 5000
VP: 5500

Unit mbar

62

0x003E

2

rP2/FL2

2 bytes

V:    rP2/FL2 >= 0
P:    rP2/FL2 >= 0
VP: rP2/FL2 >= -999

rw

V: 500
P: 4500
VP: 5000

Unit mbar

63

0x003F

1

Ou2

1 byte

0 - 1

rw

0

0 = NO
1 = NC

63

0x003F

2

Ou2

1 byte

2, 3, 128, 129

rw

3

2 = Window Mode
3 = Two-Point Mode
128 = Condition Monitoring (not for VSi P10)
129 = Diagnostic Mode

63

0x003F

3

Hy2

2 bytes

0 <= Hy2 <= FH2-FL2
V:    Hy2 < 999
P:    Hy2 < 9999
VP: Hy2 < 8000

rw

V: 20
P: 100
VP: 20

Unit mbar

80

0x0050

1

dS2

2 bytes

0 - 999

rw

0

Unit ms

80

0x0050

2

dr2

2 bytes

0 - 999

rw

0

Unit ms

108

0x006C

0

-L-

2 bytes

0 - 999

rw

200

Unit mbar/sec

40

0x0028

0

2 bytes

ro

Copy of currently active process data input

64

0x0040

1

2 bytes

ro

Actual sensor value

64

0x0040

2

2 bytes

ro

Lowest measured sensor value since power-up

64

0x0040

3

2 bytes

ro

Highest measured sensor value since power-up

66

0x0042

1

2 bytes

ro

Supply voltage as measured by the device (unit: 0.1 Volt)

66

0x0042

2

2 bytes

ro

Lowest measured supply voltage since power-up

66

0x0042

3

2 bytes

ro

Highest measured supply voltage since power-up

564

0x0234

0

1 byte

ro

0x00 = SIO mode
0x10 = IO-Link revision 1.0 (set by master)
0x11 = IO-Link revision 1.1 (set by master)

140

0x008C

0

cc1

4 bytes

ro

Switch-on counter for switch point 1 (non-erasable)

141

0x008D

0

cc2

4 bytes

ro

Switch-on counter for switch point 2 (non-erasable)

143

0x008F

0

ct1

4 bytes

ro

Switch-on counter for switch point 1 (erasable)

144

0x0090

0

ct2

4 bytes

ro

Switch-on counter for switch point 2 (erasable)

32

0x0020

0

2 bytes

ro

Number of errors since last power-up

36

0x0024

0

1 byte

ro

0 = Device is operating properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure

37

0x0025

1-15

15 x 3 bytes

ro

Information about currently pending events
Fixed-length array format according to IO-Link specification V1.1

130

0x0082

0

1 byte

ro

0 = No error
1-99 = Error code displayed by the device

138

0x008A

1

1 byte

ro

Type code of active device status (see below)

138

0x008A

2

2 bytes

ro

ID code of active device status (see below)

139

0x008B

0

1 byte

ro

Result of recent NFC activity:
0x00: Data valid, write finished successfully
0x23: Write failed: Write access locked
0x30: Write failed: parameter(s) out of range
0x41: Write failed: parameter set inconsistent
0xA1: Write failed :invalid authorisation
0xA2: NFC not available
0xA3: Write failed: invalid data structure
0xA5: Write pending
0xA6: NFC internal error

146

0x0092

0

Condition Monitoring

1 byte

ro

Bit 2: Leakage rate above limit -L- (not for VSi P10)
Bit 5: Primary voltage US outside of optimal range

160

0x00A0

0

Actual Leakage Rate

2 bytes

ro

Leakage rate, unit mbar/sec (not for VSi P10)

ID

0x0000

0x0002

0x0007

0x000A

0x0017

0x000C

0x000D

0x0015

0x0010

0x0011

0x0016

0x0000

dec

hex

4096 0x1000

16384 0x4000

20736 0x5100

20752 0x5110

30480 0x7710

35872 0x8C20

6144 0x1800

6145 0x1801

6149 0x1805

6150 0x1806

6153 0x1809

6156 0x180C

Permissible Leakage Rate

Condition Monitoring [CM]

Event code

Process Data

Communication Mode

Counters

0x42

Orange

Critical condition upper

Primary supply voltage US too high

Overtemperature

0x42

Orange

Critical condition upper

Primary supply voltage US too low

0x41

0x41

Orange

Critical condition lower

Overload OUT1

0x41

Orange

Critical condition lower

Overload OUT2

0x42

Orange

Critical condition upper

IO-Link communication interruption

0x81

Red

Defect lower

Internal parameter data invalid

Primary supply voltage US outside of operating range

Orange

0x22

Yellow

Warning upper

Sensor calibration failed

0x22

Yellow

Warning upper

Teach-In failed

Status Text

Overflow of sensor value, invalid measurement

Everything OK

Everything OK

0x21

Yellow

Warning lower

Leakage rate above limit

0x22

Yellow

New values taught for SPx, rPx or FHx, FLx, hyx

Teach-In completed successfully

Leakage rate above limit

Warning

Condition Monitoring: leakage rate above limit

Notification

Teach-In command failed

Notification

Sensor value over-run, SPx not changed (E20)

Calibration OK

Notification

Calibration offset 0 set successfully

Switch Point 2

Green

Extended Device Status - Type

Extended Device Status - ID

Error in internal data (E01)

Primary supply voltage over-run

Calibration failed

Notification

Sensor value too high or too low, offset not changed (E03)

NFC Status

Switch Point 2 - Switch-on delay

Supply Voltage HI

Error

Counter cc1

IO-Link Device Status

Communication Mode

Implemented IO-Link Events

Overload or short circuit at one or more outputs (E11 and/or E12)

Error

Error

Primary supply voltage US too low (E07)

0x10

Counter ct1

Remark

Primary supply voltage US too high (E17)

Parameter ISDU 138 - Extended Device Status

Type

Active Error Code

Counter ct2

Event type

Supply Voltage LO

Warning

Sensor Value LO

Type Color

Type Text

Warning upper

Critical condition lower

Switch Point 2 - Switch-off delay

Switch Point 2 - Window Hysteresis

Measurement range over-run

Error

Counter cc2

Event name

Diagnosis

Device Status

Overtemperature

Short circuit

General malfunction

General power supply fault

Detailed Device Status

Monitoring

Process Data In Copy

Observation

Switch Point 2 - Logic

Sensor Value

Sensor Value HI

Switch Point 2 - Upper Threshold

Switch Point 2 - Lower Threshold

Switch Point 2 - Mode

Error

Condition Monitoring [CM]

Overtemperature in electronic circuit (E19)

Primary supply voltage out of range

Warning

Condition Monitoring: primary supply voltage US outside operating range

Supply Voltage

Error Count

J. Schmalz GmbH 

2 of 2

VSi Data Dictionary

Summary of Contents for VSi D Series

Page 1: ...Vacuum Pressure Switch VSi VSi D Operating instructions WWW SCHMALZ COM EN US 30 30 01 00956 03 05 22...

Page 2: ...ished thereby Repro duction of the contents in full or in part is only permitted within the limits of the legal provisions of copyright law Any modifications to or abridgments of the document are proh...

Page 3: ...al Data 10 4 1 General Data 10 4 2 Electrical Data 10 4 3 Mechanical Data 11 4 4 Factory Settings 12 5 Installation 13 5 1 Mounting 13 5 2 Electrical Connection 13 6 IO Link Commissioning 15 7 Interfa...

Page 4: ...itching Point Settings 30 9 7 Display Screen 31 9 8 Access Rights 31 9 9 Device Identification 32 9 10 System Monitoring and Diagnostics 33 9 11 System Commands 34 10 Help with Malfunctions 35 11 List...

Page 5: ...roduct 1 For problem free and safe operation follow the instructions in the documents 2 Keep the technical documentation in close proximity to the product The documentation must be ac cessible to pers...

Page 6: ...owing points The personnel must be commissioned for the activities described in these operating instructions The staff must be at least 18 years of age and physically and mentally capable The operatin...

Page 7: ...n the sensor and actuator voltage 4 Wear the required personal protective equipment PPE when working in the danger zone CAUTION Noise pollution from leakage Hearing damage 4 Correct position 4 Wear ea...

Page 8: ...ports for the switch can be accessed using wireless communication with NFC near field communication The parameters can also be set using two buttons on the display version VSi D The current system sta...

Page 9: ...ith Display 1 2 4 8 7 5 6 3 1 Fluid connector 5 MODE button 2 Switching point 1 display ORANGE or op erating voltage display GREEN 6 Display 3 Position of the NFC antenna behind the display 7 SET butt...

Page 10: ...erty VSi VSi D Power consumption where U 24 V 35 mA 35 mA Display 3 digit 7 segment display with decimal point Display resolution Vacuum 1 mbar Pressure 10 mbar Analog output VSi V SA only 1 to 5 V co...

Page 11: ...pe L L1 G3 G11 G2 1 LG1 D VSi M8 4 38 0 55 0 M8x1 male thread G1 8 male thread M5 female thread 8 19 6 VSi M12 4 38 0 56 0 M12x1 male thread VSi D M8 4 60 5 77 5 M8x1 male thread VSi D M12 4 60 5 78 5...

Page 12: ...00 mbar 20 mbar 20 mbar Switch on delay dS1 switch off delay dr1 0 ms Transistor function PNP Switching point 2 Switching point mode and logic Two point mode normally closed H no Not available Switchi...

Page 13: ...onnection 5 2 1 Mounting the Connection Cable CAUTION Changing output signals when the product is switched on or plug is connected Personal injury or damage to property 4 The electrical connection mus...

Page 14: ...ach the union nut at position 10 with a maximum tightening torque of 0 8 Nm The plug must not twist or be subjected to any torque load 0 Nm If the plug is subjected to torque during mounting the torqu...

Page 15: ...ach switch a junction of several C Q cables is not possible with only one IO Link master port The IO Link master must be connected in the configuration of the automation system in the same way as othe...

Page 16: ...nal types for each signal output The setting is independent of the version The vacuum switch is factory set to PNP 7 2 Analog output Only the version VSi V SA has an analog output The integrated senso...

Page 17: ...er mirrors all setting parameters for the device in a sepa rate non volatile memory When a device is swapped for a new one of the same type the setting parame ters for the old device are automatically...

Page 18: ...d service app This per mits not only read access but also active reconfiguration of the parameters via NFC The Schmalz ControlRoom app is available at the Google Play Store The following instructions...

Page 19: ...e in millibar kilo pascal inch hg and PSi The information displayed varies depending on the device version and the position of the measurement value in the vacuum and pressure range Measure ment value...

Page 20: ...t range In this case the desired range for the new value is set at the start of the editing process The text Pr5 for pressure or vAC for vacuum will firstly flash and can be selected accordingly For n...

Page 21: ...r 2 seconds the system automatically returns to the 5P1 menu parameter Example of Setting the Mode Changing switching point mode 1 from x no to C no The switch is located in the Extended Functions EF...

Page 22: ...1 minute write protection is activated The entry of an invalid PIN is rejected with the message LoC 8 6 Leaving the Menu Automatically The menus automatically close if no buttons are pressed for 1 mi...

Page 23: ...on switching output 2 see Ou1 d51 Switch on delay for switching point 1 In ms this parameter is not displayed in the menu if the switching point is in condition monitoring mode C no dr1 Switch off del...

Page 24: ...erial numbers are 9 digit whole numbers These numbers are divided into 3 blocks of 3 numbers when shown on the display One of the decimal points will flash to indicate whether it is refer ring to the...

Page 25: ...ch IO Link Device Access Locks Page 32 Extended device access locks See ch Extended Device Access Locks Page 32 Menu PIN See ch PIN Code for Write Protec tion Page 31 NFC PIN Access Rights PIN Code fo...

Page 26: ...easurement range is transmitted instead of a measurement value see Special Values in the data dictionary These numbers should not then be interpreted as measurement values but as an indicator of an ov...

Page 27: ...x as a pressure switch or vacuum switch Values are considered bigger when they are further from zero and as smaller when they are closer to zero The following diagram shows the switching point behavio...

Page 28: ...to window mode the current switching points SPx and rPx are interpreted as window points FHx and FLx They are the same internal parameters also see the data dictionary If the resulting set of paramete...

Page 29: ...case the switching point is also activated when the leakage monitoring issues a warning With the V and VP8 versions diagnostics mode also includes the functionality of the condition monitoring mode at...

Page 30: ...can only be defined for the switching point SP1 In Con dition monitoring mode the parameters dSx and drx are also not shown on the display Due to the switch on and switch off delay short term fluctuat...

Page 31: ...the counter statuses and serial numbers 9 7 3 ECO Mode The product offers the option of switching off or dimming the display to save energy ECO mode can be activated and deactivated in the EF menu un...

Page 32: ...celed using IO Link not on the device itself 9 8 3 Extended Device Access Locks In the extended device access locks parameter you have the option of completely preventing NFC access or limiting it to...

Page 33: ...the switch and can be queried The maximum and minimum values can be reset via IO Link or NFC during operation using the appropri ate system commands For pressure vacuum HI LO this can also be done in...

Page 34: ...nal injury 4 Avoid possible danger zone 4 Remain vigilant All the setting parameters for the product are reset to factory settings using this function The function for resetting factory settings does...

Page 35: ...Hold the reader at the intended po sition on the product for longer No parameters can be changed using the NFC function The PIN for NFC write protection is activated via IO Link 4 Enable the NFC writ...

Page 36: ...neumatic connection before CAL is carried out E07 Under volt age US Supply voltage is too low 4 Check power supply unit and power load E08 Communica tion canceled IO Link communication canceled withou...

Page 37: ...white spirit or thin ners Only use cleaning agents with a pH between 7 and 12 2 Remove dirt on the exterior of the device with a soft cloth and soap suds at a maximum tempera ture of 60 C Make sure t...

Page 38: ...ith its corresponding operating and assembly instructions In the case of inappropriate handling or use of force any warranty and liability claims shall be void Damage and defects resulting from inadeq...

Page 39: ...Disposing of the Product 1 Dispose of the product properly after replacement or decommissioning 2 Observe the country specific guidelines and legal obligations for waste prevention and disposal 14 2 M...

Page 40: ...00 M12 4 PUR M8 4 female connector with M12 4 plug 21 04 05 00264 Connection cable VSi ASK S B M12 4 5000 M12 4 PUR M12 4 female connector with M12 4 plug 21 04 05 00265 Screw in tool MONT VORR MON VS...

Page 41: ...EN ISO 12100 Safety of machinery General principles for design Risk assessment and risk reduction EN 61000 6 1 Electromagnetic Compatibility Immunity EN 61000 6 4 A1 Electromagnetic compatibility Par...

Page 42: ...ting locked with pin code 91 0x005B 0 2 bytes 0 999 rw 0 Pass code for writing data from NFC app 73 0x0049 0 P n 1 byte 0 1 rw 0 0 PNP 1 NPN 74 0x004A 0 uni 1 byte 0 3 rw 0 0 mbar 1 kPa 2 inHg 3 psi 7...

Page 43: ...or VSi P10 Bit 5 Primary voltage US outside of optimal range 160 0x00A0 0 Actual Leakage Rate 2 bytes ro Leakage rate unit mbar sec not for VSi P10 ID 0x0000 0x0002 0x0007 0x000A 0x0017 0x000C 0x000D...

Page 44: ...J Schmalz GmbH EN US 30 30 01 00956 03 05 22 Subject to technical changes without notice...

Reviews: