These Operating instructions are intended for fitters who are trained in handling the product and who can operate
and install it.
2.5 Workplace Requirements
The following requirements must be fulfilled to ensure a safe workplace:
•
The Mechanical clamp must not be used outdoors.
•
The type plate and warning signs must be legible.
•
The surroundings of the Mechanical clamp must be dry.
•
The operator must have a clear view of the whole working area, the workplace must be adequately lit and
free of glare, and the area around the workplace must be clean and clear.
2.6 Modifications to the Product
Schmalz assumes no liability for consequences of modifications over which it has no control:
1. The product must be operated only in its original condition as delivered.
2. Use only original spare parts from Schmalz.
3. The product must be operated only in perfect condition.
3 Product Description
3.1 Description of Mechanical Clamp VCMC
3.1.1 Use
The VCMC is used for clamping dry, rigid workpieces. It may be used only in combination with suitable vacuum
clamping consoles. The clamping force and stroke are powered by evacuation of the VCMC. Since the contact sur-
face of the VCMC and the vacuum block are at the same height, you can clamp a workpiece in mixed operation as
well.
3.1.2 The Adjustment Mechanism
The VCMC is equipped with a quick-adjustment mechanism. It allows adjusting the clamping range in steps of
5 mm to conform to the workpiece.
3.1.3 Clamping the Workpiece
When the vacuum is activated (evacuation of the vacuum circuit of the suction cup mounting) by the higher-level
machine, the lifting cylinder is activated and the workpiece is clamped.
EN-US · 30.30.01.03042 · 00 · 10/21
5 / 13