Inhaltsverzeichnis / Contents

 

1

 

Sicherheits- und Gefahrenhinweise / Safety Notes ....................................................................................................... 2

 

2

 

Technische Daten / Technical data ............................................................................................................................... 4

 

3

 

Beschreibung / Description ........................................................................................................................................... 5

 

4

 

Wartung / Maintenance ................................................................................................................................................. 6

 

5

 

Ersatz- und Verschleißteile / Spare and consumable parts .......................................................................................... 7

 

6

 

Konstruktionszeichnung / Construction drawing ........................................................................................................... 8

 

7

 

Herstellererklärung / EC-declaration of manufacture .................................................................................................... 9

 

 

Anhang / Appendix 

Ejektor / SEG-20-HS-SDA 

30.30.01.00057 

 

 

1  Sicherheits- und Gefahrenhinweise / Safety Notes 

Gefahr

 

Gefahr

 

 

1.1 Allgemeine Hinweise 

 

Diese Bedienungsanleitung enthält wichtige 

Informationen zum Umgang mit dem Greifsystem. Bitte 

lesen Sie die Bedienungsanleitung sorgfältig durch und 

bewahren Sie diese für spätere Zwecke auf! 

 

Die Bedienungsanleitung ist auf den Lieferumfang der 

Fa. Schmalz abgestimmt. Kundenseitige Änderungen 

des Greifsystems wurden dabei nicht berücksichtigt! 

 

Der Anschluss und die Inbetriebnahme des Greifsystems 

darf erst erfolgen, nachdem die Bedienungsanleitung 

gelesen und verstanden wurde! 

 

Der Betrieb in explosionsgefährdeter Umgebung ist nicht 

zulässig. Brand- und Explosionsgefahr! 

 

Betrieb des Gerätes ausschließlich mit den für die 

Komponenten jeweils angegebenen 

Betriebsspannungen! 

 

Die Installation darf nur von qualifiziertem Fachpersonal 

durchgeführt werden! 

 

Allgemeine Sicherheitsvorschriften, EN-Normen und 

VDE-Richtlinien müssen beachtet und eingehalten 

werden! 

 

Betrieb des Systems ausschließlich durch geschultes 

Personal! 

Gefahr

 

Gefahr

 

 

General notes 

 

These operating instructions contain important 

information on using the gripping system. Please read 

the operating instructions thoroughly and keep them for 

later reference! 

 

The operating instructions are tailored to the scope of 

delivery of the company Schmalz. Modifications to the 

gripping system requested by the customer were not 

taken into consideration! 

 

The connection and the commissioning of the gripping 

system may only occur once the operating instructions 

have been read and understood! 

 

The device may not be operated in environments where 

there is a risk of explosion. Risk of fire and explosion! 

 

The device must only be operated using the specified 

operating voltage! 

 

The installation may only be carried out by qualified 

specialist personnel! 

 

General safety instructions, European standards and 

VDE guidelines must be taken into account and 

observed! 

 

The system may only be operated by trained personnel! 

 

Summary of Contents for SSP 10.01.10.05381

Page 1: ...03 259 www schmalz com schmalz schmalz de DE EN Greifsystem SSP Gripper system SSP 10 01 10 05381 Schmalz Saugerspinne zur Handhabung von Holzbrettern Schmalz Suction pad system for handling of wooden...

Page 2: ...wurde Der Betrieb in explosionsgef hrdeter Umgebung ist nicht zul ssig Brand und Explosionsgefahr Betrieb des Ger tes ausschlie lich mit den f r die Komponenten jeweils angegebenen Betriebsspannungen...

Page 3: ...e Auftragsbest tigung Die Saugerspinne wird an einen Roboter angebunden und mit den entsprechenden Schutzeinrichtungen betrieben Der Roboter muss von bef higtem und eingewiesenem Fachpersonal betriebe...

Page 4: ...l data Anzahl Saugstellen Number of suction cells 9 Anzahl Saugkreise Number of vacuum circuits 3 Anzahl Sauganschl sse Number of suction connections 9 Traglast Payload max 15 kg Arbeitstemperatur Ope...

Page 5: ...he customer of the basic ejector C On the basic plate B it is possible to connect a SBX Large Area vacuum gripper with several tongues for T slots The SBX Large Area vacuum gripper will be connected l...

Page 6: ...im Anhang Siehe Dokument im Anhang Siehe Dokument im Anhang Vakuumschalter Wartung gem Dokumentation im Anhang Siehe Dokument im Anhang Siehe Dokument im Anhang Elektromagnetventil Wartung gem Dokumen...

Page 7: ...ies to spare parts where these are original parts supplied by us We will assume no liability for damage caused by the use of non original spare parts and accessories Wear and consumable parts are not...

Page 8: ...ual gripper system 30 30 01 00387 Status 05 2013 Index 00 Seite Page 8 9 J Schmalz GmbH Aacher Stra e 29 D 72293 Glatten Tel 49 0 7443 2403 0 Fax 49 0 7443 2403 259 www schmalz com schmalz schmalz de...

Page 9: ...gripper system 30 30 01 00387 Status 05 2013 Index 00 Seite Page 9 9 J Schmalz GmbH Aacher Stra e 29 D 72293 Glatten Tel 49 0 7443 2403 0 Fax 49 0 7443 2403 259 www schmalz com schmalz schmalz de 7 H...

Reviews: