9 Cleaning the Compact Terminal
1. For cleaning, do not use aggressive cleaning agents such as industrial alcohol, white spirit or thinners. Only
use cleaning agents with pH 7–12.
2. Remove dirt on the exterior of the device with a soft cloth and soap suds at a maximum temperature of 60° C.
Make sure that the compact terminal is not soaked in soapy water.
3. Ensure that no moisture gets into the electrical connection.
10 Connecting the SCTSi to the Compressed Air and Power Supply
WARNING
The Compact Terminal is not screwed or secured to the threaded rods.
When compressed air is supplied, individual components are accelerated and fly around. There is a
risk of injury.
4
Before switching the Compact Terminal on again, mount the threaded rods with thread locking
compound.
1. Secure the SCTSi at the place of use.
2. Connect the compressed air and vacuum. If there is a larger number of ejectors, we recommend using an ad-
ditional compressed air supply via an intermediate feed.
3. Mount the electrical connections.
4. Switch on the SCTSi via the control unit. The new configuration is automatically detected by the control unit.
Following conversion, the type plate of the SCTSi is no longer correct.
11 Checking for Correct Installation and Function
Before starting the handling process, check for proper installation and function.
8 / 8
EN-US · 30.30.01.01934 · 00 · 03/19