1.5 Type Plate
The type plate contains important information regarding the vacuum reservoir.
The type plate is attached to the exterior of the device. It is permanently attached to the vacuum reservoir and
must always be clearly legible.
It includes the following information:
•
Part sales designation/type
•
Article/part number
•
Manufacturing date
•
CE label
Please specify all the information above when ordering replacement parts, making warranty claims or for any
other inquiries.
2 Fundamental Safety Instructions
2.1 Intended Use
The vacuum reservoir is built in accordance with the latest standards of technology and is delivered in a safe oper-
ating condition.
The vacuum reservoir VOL from Schmalz is used to maintain a specific vacuum volume.
Neutral gases in accordance with EN 983 are approved as evacuation media. Neutral gases include air, nitrogen and
inert gases (e.g. argon, xenon and neon).
Before conveying a gas, check whether the gas can be conveyed safely in the specific application.
Corresponding security measures on systems and devices that are connected to the vacuum reservoir must be im-
plemented in order to avoid danger to persons, animals or property caused by a drop in vacuum.
The product is intended for industrial use.
Intended use includes observing the technical data and the installation and operating instructions in this manual.
2.2 Safety Instructions
WARNING
A powerful vacuum flow creates a strong suction effect
Risk of injury to eyes or other body parts
4
Wear eye protection.
4
Do not look or reach into any vacuum vent.
4
When the vacuum generator is switched on, maintain a safe distance from the vacuum vent.
WARNING
Extraction of hazardous media, liquids or bulk material
Personal injury or damage to property!
4
Do not extract harmful media such as dust, oil mists, vapors, aerosols etc.
4
Do not extract aggressive gases or media such as acids, acid fumes, bases, biocides, disinfectants
or detergents.
4
Do not extract liquids or bulk materials, e.g. granulates.
2.3 Modifications to the Product
Schmalz assumes no liability for consequences of modifications over which it has no control:
1. The product must be operated only in its original condition as delivered.
2. Use only original spare parts from Schmalz.
3. The product must be operated only in perfect condition.