OPERATING INSTRUCTIONS
59
C2 rondo
Version: 27200 - D
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
Please observe:
•
The mains power connection must be a fixed connection.
•
Under no circumstances must there be any conducting connection between the metal
parts of the motor and the water.
•
An earth leakage circuit breaker (nominal fault current
£
30 mA) must be fitted to the
mains power connection.
•
At the marked connection terminal (at the foot of the motor or next to the terminal box)
an equalising potential with a cross-section of 10 mm² must be fitted.
5.2
Electrical connections AC
Protective measures:
fig. 26
Mains voltage
230 V for 1 ~ AC
Mains power supply cable: 3 x 2.5 mm²
Pump power supply cable: 3 x 2.5 mm²
Fuse:
16 A passive
B
=
Control unit in the pool
M
=
Motor of the circulation pump
N
= Mains
power
supply
(230 V for 1~)
S
= Switchgear
cabinet
C
B
= Capacitor
Connection cable, for example,
HO7RNF, all further details required for
making connections can be found in
chapter 3.1.
fig. 27: Basic circuit diagram for 230 V
for 1 ~ AC
An earth leakage circuit breaker
(nominal fault current
£
30 mA) must be
fitted to the mains power supply!
Important: Watch the order of the
terminal bridges!
See the inside of the terminal box lid or
enclosed circuit diagram. Please be sure
to observe instructions from the motor
manufacturer!
L
External conductor
N
Neutral conductor
8236
8206