OPERATING INSTRUCTIONS
58
C2 rondo
Version: 27200 - D
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
4.11.4
Face plate assembly installation / Wooden-liner pool
5
Electrical connections
5.1
Electrical Connections - general
The electrical connections to the counter-current swimming system must be carried out by
a specialised company in the electrical engineering branch approved by the local energy
provider, taking into account the technical connection requirements.
fig. 25
10
Suction housing
21
Switching tube
30
Clamp ring
35
Face plate assembly
90.3
Screw
After connecting the air button, put on the
face plate assembly (35), this allows the
pressure connection and air connection
to slide into one another. Fasten to the
clamp ring (30) with the screws (90.3).
Warning!
Make sure that there is not a kink in the
switching tube (21), lay it in a loop and do
not shorten!
Warning! Mortal danger!
The connections must be carried out by a qualified electrician. For this see for
example the
Technical Connection Conditions for heavy Current from the
power supply company
, the
Regulations of the Electrical Trade VBG (§3)
and
DIN VDE 1000-10 / 1995-5.
The relevant
DIN VDE directives 0100
and
where there is a risk of explosion
0165
must also be observed. If the installation
is not carried out properly, there is a risk of getting electric shocks!
Warning!
Compare the available power supply voltage with the details on the motor’s
factory plate and select the appropriate switching.
We recommend the use of a motor protection facility. Explosion protected
motors, increased safety (Ex)–e and temperature class T3, must always be
connected in accordance with DIN VDE 0170/0171 via a motor protection
switch.
Connect the motor in accordance with the circuit diagrams in the following
chapters.
8438