PAGE 47
© 2015. All rights reserved. Used under license by Schlüter-Systems KG.
Sensor Application
This option allows you to choose which sensor is used to control the heating
system.
• Floor (default): With this setting, the floor sensor controls the heating system.
• Room/Floor Limit (advanced): With this setting, the room sensor controls the
heating system subject to maximum and minimum limits for floor temperature.
The maximum temperature limit protects wooden floors from excessive heat.
The minimum temperature limit prevents the floor from becoming uncomfortably
cold when heating is not needed, e.g. in a bathroom. Note that this function will
increase energy consumption.
Floor Limit temperatures are set in the “Temperature Scale” menu.
Maximum temperature depends on floor type and temperature scale.
1. Tap the “
Menu
” button on the home screen.
2. Then tap the “
Engineer Settings
” button.
3. Tap the “
Sensor Application
” button.
4. Confirm that you want to set the Sensor Application.
5. Then tap the application you want to use.
6. Confirm your choice with “
√
” or discard it with “
X
”.
7. The thermostat will automatically return to “
Engineer Settings
”.