9
WPR400 Wireless Portable Reader User Guide
RESET TO FACTORY DEFAULTS
!
All information in the WPR400 will be deleted and reset to factory defaults!
Level 1 Factory Default Reset
Level 1 factory default reset will delete all
Lock Settings
as found
in the “Edit” tab on the “Lock Properties” screen on the SUS.
Edit Tab
1. Remove the WPR400 cover.
2. Press and hold Schlage button until
two (2) beeps sound (10 seconds).
3. Release the Schlage button.
4. Press and release the IPB three (3) times.
The top LEDs will fl ash when the reset is complete.
5. Replace the cover.
Level 2 Factory Default Reset
Level 2 factory default reset will delete all the
Reader Settings
as found in the “Reader” tab on the “Lock Properties” screen on
the SUS.
Reader Tab
To complete Level 2 factory default reset, repeat steps 2 through 4 above
within 10 seconds of
the confi rmation signals of Level 1 factory default reset.
If more than 10 seconds pass after the
confi rmation signals of Level 1 reset, then Level 1 reset will be repeated.
WPR400 LED REFERENCE
Link Mode LED Reference
Schlage LEDs
Beeps
Action
1 Red, 1 Green
0
One link request was sent to fi nd a PIM400 in link mode.
This action will repeat twice, then stop.
1 Green
0
Successful RF packet transmission
1 Red
0
Unsuccessful RF packet transmission
Z Green
1
Z
2
Link was successful
3 Red
5
Link was unsuccessful
1 Z = RF channel number on which the WPR400 is linked (1-10). The RF channel of each PIM400 in the area
should be known and recorded.
2 Number of beeps should match the RF channel number of the PIM400.
Normal Operation LED Reference
Schlage LEDs
Action
Green
A valid credential was presented to the WPR400 reader
Red
An invalid credential was presented to the WPR400 reader
Inside Push Button