Maintenance

Change the Sensor Battery

a. 

Press the tab on the top of the Sensor and pull forward to remove the front cover.

b. 

Remove the old battery.

c. 

Insert a new 3V CR123A battery. Observe polarity.

d. 

Replace the Sensor front cover.

Note: Sensor enrollment is not required after battery change.

 SAFETY HAZARD!  

BATTERY MAY EXPLODE IF NOT PROPERLY HANDLED.

 

DO NOT RECHARGE, DISASSEMBLE OR DISPOSE OF IN FIRE.

If necessary to remove a Sensor from the Nexia account, follow these steps to exclude the Sensor from
a Z-Wave Network:

a. 

Install a fresh, high-quality 9-volt battery into the Bridge.

b. 

Hold the Bridge within 6 feet (1.8 meters) of the Sensor during the entire exclusion process.

c. 

Press and release the “–” button on the Bridge.

d. 

Remove the battery from the Sensor.

e. 

Leave the battery out for at least ten (10) seconds.

f. 

Reinstall the battery into the Sensor.

g. 

Observe lights on the Bridge. The orange LED will blink rapidly while exclusion is taking place. Exclusion is complete when the 
orange LED lights solid.

h. 

Remove the battery from the Sensor after exclusion is complete.

For more information, refer to the Nexia Home Bridge User Guide.

FCC Statement

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation.

Changes or modifi cations to this equipment not expressly approved by the Schlage could void the user’s authority to operate the equipment.

FCC ID: P2GBE369  IC: 7654A-BE369

nexiahome.com

U.S.A. /Canada
(877) 288-7707

Summary of Contents for NXRS100HC

Page 1: ...de The Sensor s LED will blink If the plastic tab is already removed then remove the battery for 10 seconds and replace the battery to restart enrollment mode Battery removal process shown below c The orange LED on the Bridge will blink rapidly when enrollment begins The Bridge and Sensor LEDs will light solid to indicate successful enrollment If the Bridge LED never blinks rapidly and enrollment ...

Page 2: ...or the browser to refresh LIGHTING MODULES CAMERAS CLIMATE SECURITY SENSORS CLOSED Setup Device New Sensor 3 Sensors Locks Security Sensors New Sensor Sensor Type Door Alerts Alert when opened Alert when closed Save Changes Cancel s s C CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor Figure 1 Figure 2 Figure 3 Door Sensor Wind...

Page 3: ... wallboard Left hand door OR Right hand door OR The top of the magnet must be within 6 mm of the arrow on the Sensor as shown above Install the magnet no more than 19 mm away from the Sensor for optimal performance Install the Magnet with screws a Remove the base from the magnet b Use two small screws to attach the base of the magnet to the door or window c Press the magnet onto the base OR Instal...

Page 4: ... Press and release the button on the Bridge d Remove the battery from the Sensor e Leave the battery out for at least ten 10 seconds f Reinstall the battery into the Sensor g Observe lights on the Bridge The orange LED will blink rapidly while exclusion is taking place Exclusion is complete when the orange LED lights solid h Remove the battery from the Sensor after exclusion is complete For more i...

Reviews: