Schlage NXRS100HC Installation Instructions Download Page 1

1

Prepare the Nexia Bridge for Enrollment. Choose and follow the easiest option for you shown below.

Battery powered Bridge:

•  Disconnect Ethernet and power to the Bridge.
•  Install a fresh, high-quality 9-volt battery into the Bridge.
•  Move the Bridge to within 6 feet (1.8 meters) of the Sensor. Keep the Bridge in this position during the entire enrollment process.

AC powered Bridge:

•  Move the Sensor to the Nexia Bridge for enrollment.
•  Keep the Sensor within 6 feet (1.8 meters) of the Nexia Bridge during the entire enrollment process.

For more information, refer to the Nexia Bridge User Guide.

2

Activate and Enroll the Sensor

a. 

Press and release the “+” button on the Bridge. The orange 
LED will blink slowly to indicate enrollment mode. 

The Bridge 

will remain in enrollment mode for 30 seconds before 
timeout.

b. 

Remove the Sensor’s plastic pull tab to activate battery 
power and start the Sensor’s enrollment mode. The Sensor’s 
LED will blink.

 

! If the plastic tab is already removed, then remove the 
battery for 10 seconds and replace the battery to restart 
enrollment mode. (Battery removal process shown below.)

c. 

The orange LED on the Bridge will blink rapidly when 
enrollment begins. The Bridge and Sensor LEDs will light 
solid to indicate successful enrollment.

 

! If the Bridge LED never blinks rapidly and enrollment mode 
times out (after 30 seconds), then repeat steps a-c.

Battery removal and replacement

+

 

Orange 

LED

+

Button

b.

a.

Door/Window Sensor Installation Instructions

Product Overview

•  Z-Wave™ enabled device which provides open/closed position status
•  Transmits open/closed status
•  Reports tamper condition when cover is open
•  Battery life approximately 3 years

Product Specifi cations

•  For indoor use only
•  Operating frequency: 908.42 MHz
•  Operation range: Up to 100 feet (30.5 meters) line-of-sight
•  Operating temperature: 0° – 49°C, 32° – 120°F (ambient temperature)
•  Battery type required: 3V Lithium CR123A
•  Battery life approximately 3 years



P516-485

DO NOT plug in Ethernet or power before enrolling!

Optional Installation Tool

Summary of Contents for NXRS100HC

Page 1: ...de The Sensor s LED will blink If the plastic tab is already removed then remove the battery for 10 seconds and replace the battery to restart enrollment mode Battery removal process shown below c The orange LED on the Bridge will blink rapidly when enrollment begins The Bridge and Sensor LEDs will light solid to indicate successful enrollment If the Bridge LED never blinks rapidly and enrollment ...

Page 2: ...or the browser to refresh LIGHTING MODULES CAMERAS CLIMATE SECURITY SENSORS CLOSED Setup Device New Sensor 3 Sensors Locks Security Sensors New Sensor Sensor Type Door Alerts Alert when opened Alert when closed Save Changes Cancel s s C CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor Figure 1 Figure 2 Figure 3 Door Sensor Wind...

Page 3: ... wallboard Left hand door OR Right hand door OR The top of the magnet must be within 6 mm of the arrow on the Sensor as shown above Install the magnet no more than 19 mm away from the Sensor for optimal performance Install the Magnet with screws a Remove the base from the magnet b Use two small screws to attach the base of the magnet to the door or window c Press the magnet onto the base OR Instal...

Page 4: ... Press and release the button on the Bridge d Remove the battery from the Sensor e Leave the battery out for at least ten 10 seconds f Reinstall the battery into the Sensor g Observe lights on the Bridge The orange LED will blink rapidly while exclusion is taking place Exclusion is complete when the orange LED lights solid h Remove the battery from the Sensor after exclusion is complete For more i...

Reviews: