Indicator Table
Condition
LED Indicator
Audible
Alarm Relay State
Standard Features
Lock Secure
Off
Off
Open
Authorized Release Input
Steady Green
Off
Open
During Nuisance Delay
Steady Red
Off (Default)
Set by SW2-3
Open
During Fire Alarm
Steady Green
Off
Closed
During Delayed Egress
Flashing Red
Beeping
Closed
After Delayed Egress
Steady Green
Steady Tone
Closed
Switch Selectable Features
SW2-7 "ON" = Unlock Alert whenever lock is unlocked
Steady Green
Steady Tone
Open
SW2-3 "ON" = Horn will sound during nuisance alert
Steady Red
Steady Tone
Open
Optional Switch Selectable Features - Plus Model Required
Door Propped Open Alarm
Flashing Green
Beeping
Closed
Door Forced Open Alarm
Flashing Red
Steady Tone
Closed
Door Forced Open Alarm followed by Delayed Egress Input
Steady Green + Flashing Red
Steady Tone
Closed
Troubleshooting
Condition
LED Indicator
Lock has power but won’t lock. LED (on lock) is Green.
Fire alarm not connected or open connection. SW4-7 not ON (set switch, remove and
re-apply power).
Won’t go into delayed egress.
Check dipswitch settings
Armature washers not installed properly
Magnet not properly aligned with armature.
Goes into delayed egress upon powerup.
Armature washers not installed properly
Improper gap between magnet and armature
Lock can be pushed open with minimal resistance.
Magnet/Armature/washers not installed properly
Lock “hums” or vibrates noisily when energized.
Magnet/Armature/washers not installed properly
LED(s) flash once quickly.
Relock delay set to 0 sec.
Keypad not initialized
MBS doesn’t change state when locked.
Low voltage. Mechanical misalignment. Debris between lock and armature. Armature/
magnet not installed properly
DPS option not working properly.
Armature holder not aligned with DPS switch.
Switch not plugged into correct jack
BOCA Operational Description
L
BOCA Option is Applicable in United States Jurisdictions Only
a. Lock the door and start the release process by pushing on the actuating bar (or door if no actuating bar provided) for at least 1 second.
The door will release within 15 seconds.
b. The door will not relock until the door has been opened, and returned to the closed position for not less than 30 seconds. Any reopening
of the door during this time will restart the 30 second relocking cycle.
c.
A 30 second release time delay may be provided with code official approval.