HandKey II Manual
65
Terminal 1 and the center pin of jack J12 are connected together. Terminal 2 and the
sleeve of jack J12 are connected together.
Use any one of the following ground terminals to make the earth ground connection: 8,
10, 12, 14, 18, 20, 22, 24, or 26. Do NOT use terminal 2 to establish the earth ground
connection; terminal 2 is not directly connected to ground.
15 16 17 18 19 20 21 22 23 24 25 26
15
16
17
18
19
20
21
22
23
24
2625
OUTPUTS
GR
OUND
GR
OUND
GR
OUND
GR
OUND
GR
OUND
+5
VDC OUTPUT
DA
TA
INPUT
CLOCK INPUT
LOCK OR CLOCK
BELL OR D
ATA
AUXOUT
1
AUXOUT
2
EARTH GROUND CONNECTION PINS
CARD
READER
INPUT
Figure 19-8: Earth Ground Connection Terminals
There are two standard methods for providing earth grounding to HandPunch units:
•
earth grounding all units (see page 10)
•
carrying an earth ground to each unit (see page 11)
Earth ground all units when there is a good earth ground source near each unit and/or
when there are very long cable runs between units.
Carry an earth ground to each unit when there are no earth grounds convenient to the
unit and the unit’s power supply is floating.
Grounding
NOTE
!
NOTE
!
Summary of Contents for HK-CR
Page 1: ...HK CR Terminal User s Guide ...
Page 18: ...This page intentionally blank ...
Page 32: ...This page intentionally blank ...
Page 34: ...This page intentionally blank ...
Page 40: ...This page intentionally blank ...
Page 48: ...This page intentionally blank ...
Page 54: ...This page intentionally blank ...
Page 60: ...This page intentionally blank ...
Page 86: ...This page intentionally blank ...
Page 87: ......