background image

GF3000 SERIES INSTALLATION MANUAL

Installing a GF3000 Series Lock

Installing the Lock - Standard, TRD, TJ, SM

1)  Mounting Tabs (Standard, TRD):

2)  Surface Mount Armature Housing Sex Bolt Hole Sizes (TJ, SM):

Secure two mounting tabs (

a

) to ends of lock cutout in frame.  Mounting tabs can be installed upside-

down (

b

 hollow metal or 1/8” thick aluminum frames.

a

a

b

Door Types:

• 

    

A

 = Hollow Metal

• 

    

B

 = Reinforced

• 

    

C

 = Solid Wood

Hole Sizes and Parts:

• 

    

a

 = sex bolt

• 

    

b

 = 1/2” hole

• 

    

c

 = 1/4” hole

• 

    

d

 = mounting spacer

• 

    

e

 = armature

• 

    

f

 = 1/4-20 x 2

• 

    

g

 = inside of door

     

h

 = 1/4-20 threaded hole (thru reinforced side

of door only)

a

d

a

b

b

c

d

d

e

e

e

f

f

f

g

g

g

A

B

C

h

Page 8

) so that they may be used with 16 gauge

Summary of Contents for GF3000 Gravity Force Series

Page 1: ... Models Covered Standard TRD BRD SM and TJ Gravity Force Shear Locks Mortise Surface Mount INSTALLATION MANUAL GF3000 Allegion 2014 Printed in U S A 30500 1 15 f Customer Service 1 877 671 7011 www allegion com us ...

Page 2: ...plate information TJ 12 Template information SM 12 Mounting the Lock Standard TRD TJ SM 13 Install Armature Mounting Spacer 13 Install Faceplate 13 Attach Magnet Housing to Frame 13 Install Magnet 13 Installing the Lock BRD 14 Preparing the Floor for the GF3000BRD Magnet 14 Installing the GF3000BRD Threshold Box 15 Preparing the Door for the Armature 15 Mounting the GF3000BRD Armature in the Door ...

Page 3: ...onfirming the Box Contents Confirming the Box Contents Page 3 k b a c MAGNETIC COIL ASSEMBLY ARMATURE ARMATURE MOUNTING ASSEMBLY MOUNTING TABS HEX WRENCH SHIM PLATE HARDWARE PACK MAGNETIC COIL HOUSING ARMATURE HOUSING FACE PLATES THRESHOLD BOX a b c d e f g h i j k ...

Page 4: ...urface Mount GF3000TJ Top Jamb Tools and Materials Needed Not Included in Box Whichever model you are installing you should have all of the following tools on hand Pencil Tape Measure Hammer Center Punch Power Drill w Set of Drill Bits Chisel Small Sawsall or other metal cutting saw Set of Hex Allen Wrenches Set of Philips Head Screwdrivers Electrical Tool Kit containing wire cutter stripper elect...

Page 5: ...s Compliance UL R12092 MEA 222 96 E CSFM 3774 0544 107 Shipping Weight GF3000 6 Pounds GF3000TRD BRD 8 Pounds Dimensions Mortise Mount Magnet 9 5L x 1 5W x 1 5H Magnet w Mounting Tabs 11 56L x 1 5W x 1 5H Armature 8 38L x 1 38W x 0 5D Armature Bracket 10 63L x 1 38W x 1 0D Dimensions Surface Mount Magnet Housing 9 81L x 1 25H x 1 5D Armature Housing 8 38L x 1 38W x 0 5D Page 5 Operation Standard F...

Page 6: ...rmature assembly A1 and A2 thus forming a vertical axis AM Check door frame for any structural member or hardware component that might interfere with magnet and armature mounting areas before selecting template location Remove existing hung doors for template application and armature installation The standard model GF3000 can be installed in a horizontal or vertical configuration To achieve maximu...

Page 7: ...nes for armature A1 and A2 thus forming a vertical axis AM To achieve maximum resistance to forced entry position unit closest to latch side of door Adjusting screw must be accessible with a long bladed screwdriver when door is hung Check both door frame for any structural member or hardware component that might interfere with magnet and armature mounting areas before selecting template location E...

Page 8: ...s of lock cutout in frame Mounting tabs can be installed upside down b hollow metal or 1 8 thick aluminum frames a a b Door Types A Hollow Metal B Reinforced C Solid Wood Hole Sizes and Parts a sex bolt b 1 2 hole c 1 4 hole d mounting spacer e armature f 1 4 20 x 2 g inside of door h 1 4 20 threaded hole thru reinforced side of door only a d a b b c d d e e e f f f g g g A B C h Page 8 so that th...

Page 9: ...the Standard and the TRD models The door prep for the standard model has many options see depending on the depth of the channel if any The TRD model has a specific prep of its own see The lock should be located as close to the strike side as possible while still allowing room for the mounting tabs and screws Frame Prep Hollow Metal or Aluminum Frame Prep Wood Page 9 ...

Page 10: ...NUAL Installing a GF3000 Series Lock 4 Door Prep Standard and TRD DOOR PREP Hollow Metal or Aluminum Depth flush to 1 4 DOOR PREP Hollow Metal or Aluminum Depth 1 4 to 1 DOOR PREP Hollow Metal or Aluminum Depth 1 4 to 1 3 4 Page 10 ...

Page 11: ...Series Lock Standard and TRD Door Prep continued DOOR PREP Hollow Metal or Aluminum Depth 1 3 4 to 2 1 2 DOOR PREP Wood DOOR PREP TRD Hollow Metal or Aluminum door where the top adjustment is not accessible Depth 1 3 4 Page 11 MINIMUM 1 7 8 DOOR THICKNESS ...

Page 12: ...lling a GF3000 Series Lock 5 Template information TJ All dimensions in inches 6 Template information SM All dimensions in inches a NOTE Hole a size and type depends on door type and mounting style LEFT HAND REVERSE RIGHT HAND REVERSE Page 12 ...

Page 13: ...ousing c onto door Use through holes a a b c Install faceplate a into magnet housing Tighten set screws b a b Carefully feed wires through access hole a in magnet housing b Using either two 10 x 3 4 sheet metal screws or two 10 x 1 2 machine screws c loosely attach magnet housing to frame DO NOT COMPLETELY TIGHTEN AT THIS TIME c b a Make final wiring connections see Wiring Diagram on page 21 Inser...

Page 14: ... at the site create a pocket that is at least 2 375 wide x 7 5 long within the threshold area centered directly below door s bottom rail and furthest away from hinges Depth of this pocket d may vary from site to site The guiding dimension for depth of the pocket is dis tance e Distance e is from top of the threshold box that is inset into the pocket to the underside of the threshold plate IMPORTAN...

Page 15: ...le in threshold box Secure conduit with nut Position box in pocket and conduit in trench Pour concrete around threshold box and conduit and allow to cure Mount armature mounting bracket assembly a to bottom rail using 10 24 x 3 4 Pan head screws b supplied Mount armature assembly c to armature mounting bracket assembly a Remove end cap on door to expose adjusting screw d If door doesn t have a rem...

Page 16: ...g screw located in access hole so that the clearance gap of approx 1 16 between magnet face and armature is achieved It may be necessary to slightly re adjust the gap to achieve proper locking action and spring return action when the magnet is de energized If door s bottom raildepth is greater than 1 3 4 spacers e may be needed one 1 8 thick spacer is supplied Install door status switch into frame...

Page 17: ...me delay to relock that is adjustable from 2 to 30 seconds The unit has been preset at the factory for a 3 second relock delay 3 To Adjust Relock Time Delay 1 Refer to the wiring diagram above and note location of ATD arrow 2 With door open apply power 3 Remove 5 64 hex head screw to allow access to recessed momentary pushbutton switch 4 Using the hex wrench provided depress and release the recess...

Page 18: ... a 3 second relock delay 3 To Adjust Relock Time Delay 1 Verify that the exposed yellow wire on the ARS is not shorting against anything 2 With door open apply power IMPORTANT Do not cut yellow wire 3 Touch the violet wire to the black ARS wire one time for each second of delay required maximum 30 seconds minimum 2 seconds Example To set ATD to 5 seconds touch the violet wire to the black ARS wire...

Page 19: ...llow metal doors 1 diameter Installation of magnet and switch must be concentric common centerline Switch insertion snap in fit Magnet insertion Wood or aluminum doors press in fit Hollow metal doors snap in fit If necessary use epoxy Contact Type Single Pole Double Throw SPDT Contact Rating 28VDC 300 mA max With door closed no more than 1 2 air gap is allowed between switch an magnet Page 19 ...

Page 20: ...oor Status Monitor DSM The optional DSM provides a dry set of contacts for monitoring door open or door closed conditions Magnetic Bond Sensor MBS The optional MBS provides a dry set of contacts for monitoring door locked or door unlocked conditions The MBS measures the magnetic holding force between the armature and the magnetic coil Poor magnetic bond is the result of low voltage foreign materia...