7
CO-100 Offl ine Lock User Guide
Manual Programming Commands
Commands are confi rmed by fi ve alternating green blinks of the Schlage button.
Programming mode will time out if no entry is made in 20-25 seconds. Timeout is indicated by red
blinks of the Schlage button, three left and nine right at the same time.
The right LED on the Schlage button will blink green to indicate an incorrect entry. To interpret
blink patterns, refer to Error Codes on page 7.
Function
Press
Wait For
Confi rmation
1
Disable/Enable
Beeper
[Programming Code]
Wait for
to stop flashing
between each
step.
to disable beeper OR
to enable beeper
Change PIN Length
2
[Programming Code]
Wait for
to stop flashing
between each
step.
Press
,
,
, OR
for desired PIN length
to finish
1 Other lights may show before the fi nal confi rmation. Wait for fi nal confi rmation before continuing to the next step.
2 Change PIN length is available with fi rmware version 2.5.0 or higher.
ERROR CODES
All error codes are indicated on the Schlage button by a solid red LED and a blinking green LED.
The number of green blinks indicates the error code.
Number of
Green Blinks
Error Code Description
1
Computer programming error (not complete).
2
Too long programming/user code entered. Programming code must be fi ve (5)
digits. User code length cannot exceed eight (8) digits.
3
Memory full, too many codes. Delete some codes.
4
Programming code cannot be deleted, only changed.
5
Programming code entries do not match. Programming code not changed.
6
Invalid command. Invalid function code entered.
7
Code not found.
8
Code too short. Programming code length must be fi ve (5) digits. User code
minimum length is three (3) digits.
9
Not a unique code.
10
Manual programming not allowed.
Error code functions have not been verifi ed by Underwriters Laboratories Inc.