28
Ignis-Protect (contd.)
17.
Replace the prepared thermal board.
NOTE: The vapour barrier must
not be damaged!
16.
Cut a hole in the thermal board to
fit the Ignis-Protect outer protection
pipe.
IMPORTANT: follow the safe
working notes on page 29.
21.
Application of render over the whole
surface.
NOTE: do not render over
the inner protection pipe!
18.
If necessary, shorten the inner and
outer protection pipes to be flush
with the wall.
IMPORTANT: follow
the safe working notes on page 29.
20.
Check that the thermal insulation is
flush with the wall.
19.
By pulling out the corresponding inner protection pipes and the assembly
cap (A) the connection size is adapted to fit the required connecting pipe
or transition piece.
The Ignis-Protect
inner protection pipe and
the outer protection pipe
are basically designed for
24mm wall planking!
TIP:
The inner protection pipes
and the assembly cap (A)
remain in place until the
stove connection pipe is in
its final position in the
Ignis-Protect.
TIP:
Follow the preparation
guidelines and relevant
drying times of the
render system
manufacturer!
IMPORTANT!