background image

WIRING DIAGRAM

WIRING CHART

PART NO.

COLOR

LENGTH

  FROM

TO

1041

White

4 1/2"

Terminal Block

Valve

1041

White

4  1/2"

Flame Control Valve

Valve

1226

Red (Hi-Temp)

16 1/2"

High Limit Switch

Valve

1226

Red (Hi-Temp)

16 1/2"

Terminal Block

High Limit Switch

1226

Red (Hi-Temp)

16 1/2"

Flame Control Valve

High Limit Switch

1188

Green

6"

Flame Control (Ground)

Ground

1111

Orange

8"

Flame Control (Ignition)

Spark Plug

1959

Green

7"

Flame Control (Harness)

Ground

1959

Red

7"

Flame Control (Harness)

Terminal Block

1959

White

6"

Flame Control (Harness)

Terminal Block

1959

Black

6"

Flame Control (Harness)

Terminal Block

INSTRUCTIONS FOR ORDERING PARTS

All parts orders must show heater Model No., Item No., Part
No., and Description.  We recommend that only parts
supplied by the manufacturer be used on this unit.  A locally
purchased part may appear to be identical, although in
reality  it might endanger the heater or the persons operating
the heater.

The heater should be serviced only by a trained, experi-
enced  service person.

Read the section on "Servicing" before ordering parts.

For parts order, call (909) 981-5343.

Summary of Contents for 150-FAST

Page 1: ...IONS BEFORE YOU OPERATE THIS HEATER RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE PROPANE CONSTRUCTION National Riverside Universal MODEL SPC 150T SPC ALL PRO FORCED AIR 150 000 BTU HR HEATER SPECIFICATIONS 150 Type of Gas For Use with Propane Gas Only InputRating 150 000BTU hr FuelConsumption 7 Lbs hr Gas Supply Pressure to Regulator Max Bottle Pressure Min 5 psig Regulator Out 11 W C Fuel Orifi...

Page 2: ...98 WARNING FIRE BURN INHALATION AND EX PLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOM MENDEDBYTHEINSTUCTIONSNEVERUSETHEHEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PAR TICLES OR UNKNOWN CHEMICALS OPERATING PRECAUTIONS This is a p...

Page 3: ...OL fitting of hose and regulator assem bly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder s valve outlet and securely tighten with a wrench 4 Connect the hose to the heater by rotating the hose fitting clockwise 5 Securely tighten all gas connections 6 Open the cylinder s gas valve and check all gas connections with a soap and water solution DO NOT USEAF...

Page 4: ...33 3133 Support Motor Strap 2 7744 7744 Label Model Operating Instructions 1 15 1561 1561 Motor Assembly 1 6374 6374 Label Electrical Ground 1 16 3087 3087 Grille Inlet 1 7789 7789 Label Wiring Diagram 1 17 6225 6225 Snap Bushing 5 8 1 7067 7067 Label BTU Rating 2 18 3132 3132 Saddle Motor Support 1 6383 6752 Label Logo 2 19 6152 6152 Hose Assembly 1 7743 7743 Manual Operating Instr 1 20 6255 6255...

Page 5: ...1959 Red 7 Flame Control Harness Terminal Block 1959 White 6 Flame Control Harness Terminal Block 1959 Black 6 Flame Control Harness Terminal Block INSTRUCTIONS FOR ORDERING PARTS All parts orders must show heater Model No Item No Part No and Description We recommend that only parts supplied by the manufacturer be used on this unit A locally purchased part may appear to be identical although in re...

Page 6: ...eitherpartsorlaborand will be returned to you freight prepaid Please include a brief statement indicating date place of purchase the nature of the problem and proof of purchase Out of warrrantyproductsreturnedtotheServiceDepart mentwillberepairedwithachargeforpartsandlaborand will be returned to you freight collect TECHNICAL INFORMATION HOW MUCH HEAT DO I REQUIRE For economy it is important to mat...

Reviews: