www.scheppach.com /
+(49)-08223-4002-99 /
+(49)-08223-4002-58
72 | GB
•
Carefully clean the flange screw (28), outer flange (29) and inner flange
(31).
• Fit and fasten the new saw blade (6) in reverse order.
• Attention!
The cutting angle of the teeth, in other words the direction
of rotation of the saw blade (6) must coincide with the direction of the
arrow on the housing.
• Before continuing your work make sure that all safety devices are in
good working condition.
• Attention!
Every time that you change the saw blade (6), check to see
that it spins freely in the table insert (10) in both perpendicular and 45°
angle settings.
• Attention!
The work to change and align the saw blade (6) must be
carried out correctly.
8.11 Using the laser (fig. 18)
Switching on:
Press the ON/OFF switch laser (33) 1x. A laser line is projected onto the
material you wish to process, providing an exact guide for the
Switching off:
Press the ON/OFF switch laser (33) 1x.
8.12 Adjusting the laser (fig. 19
−
20)
If the laser (32) ceases to indicate the correct cutting line, you can re-
adjust the laser. To do so, open the screws (32b) and remove the front
cover (32a). Loosen the Phillips head screws (E) and set the laser by
moving sideways until the laser beam strikes the teeth of the saw blade
(6).
After adjusting and tightening the laser, mount the front cover by tighten-
ing both screws (32b) by hand.