Installation information

 

Technical specifications:
Flow pressure (min. – max.):  1,0 - 5,0 bar
Flow rate (recommended):  0,15 l/s (9l/min)
Flow rate: (min. – max.):  0,1 - 0,3 l/s (run times change)
Temperature: 10 °C - 45 °C (risk of scalding)
Temperature max.:  70 °C (short-term, e.g. for thermal disinfection -   ATTENTION: Risk of scalding!)

Installation information: 
Ensure adequate dimensioning in accordance with DIN 1988 Part 3, or EN 806-3.  Observe DIN 1988 Part 4 (protection of drinking water, 

compliance with drinking water quality) as well as EN 1717 (protection of drinking water against contaminants in drinking water supply  

installations).

Water qualities:
SCHELL wall-mounted basin fittings are fit to be used in drinking water systems in accordance with the Trinkwasserverordnung <Drinking 

Water Ordinance> 2001. It is inherent in the system that the fittings contain sensitive modules which must be protected against dirt particles 

and calcification. If required, provide return flush filters and decalcification systems (water from 10 ° dH). Fittings must not be operated with 

mineral water whose contents have a tendency to flocculate or which are especially aggressive towards metallic materials until it has been 

released.

General assembly information:
Use corrosion-resistant pipe materials. Seal threads with permitted sealants only (Teflon tape). Do not exceed normal torques!  

Rarely used fittings: 
Select a pipe layout which prevents stagnant water (ring installation). If required, fit flush valves behind the fittings. If used after prolonged 

operating pauses, allow water to drain (see recommendation of the Umweltbundesamt (Federal Environment Agency).

Protection against Legionella: 
If there is a risk of high Legionella concentrations, take measures in accordance with DVGW work sheet W 551.  

 

 

 

Pay particular attention to installations for persons with immune deficiencies.   

Start-up information:
Schell shower fittings are tested with perfectly hygienic water (Legionella filter). Following installation, each fitting must undergo a pressure 

test which should be conducted preferably with compressed air. Check the temperature setting of the thermostat, hot water safety device  
(38 °C ± 1 °K).

Fittings with temperature limit:
ATTENTION: No scald protection, temperature mix ratio changes at higher hot water temperatures. If required, fit central thermostats.

Fittings vor premixed water:
To prevent the risk of scalding, select appropriate operating temperatures for the hot water supply. If required, fit central thermostats.

External installation:
ATTENTION: If there is a risk of frost, drain fittings, remove functional components or permanently protect fittings with thermal tape.

Information refers to for self-closing fittings WB-SC-M und WB-SC-V only:

  

All fittings have been tested for function at the factory and set for a run time of approx. 15 – 20 s at the following values:

1. 

Flow pressure: 3 bar

2. 

Mix water temperature: 38 °C

3. 

Shower head flow rate: 10 l/min 

Other pressures, flow rates and temperature changes will result in different run times:  

1. Run time changes caused by flow pressure changes
  Higher pressure – shorter run time
  Lower pressure – longer run time

2. Run time changes caused by different flow rates
  Lower flow rate – shorter run time
  Higher flow rate – longer run time 

3. Run time changes caused by temperature changes
  Lower temperature – longer run time
  Higher temperature – shorter run time

The run time can be set to a flow pressure of 3 bar between 

approx. 5 and approx. 20 s via the regulating needle. Run time fluctuations 
resulting from pressure fluctuations within the mains supply are normal.

Summary of Contents for 01 828 06 99

Page 1: ...orgemengd water Art Nr 01 829 06 99 F Instructions de montage set encastrer Masterbox WB SC M Temporis e Eau m lang R f 01 828 06 99 Masterbox WB SC V Temporis e Eau pr m lang R f 01 829 06 99 G Assem...

Page 2: ...onzentrationen zur thermischen Desinfektion Ma nahmen entsprechend DVGW Arbeitsblatt W 551 vorsehen Besondere Beachtung bei Installationen f r Personen mit Immunschw chen Hinweise bei der Inbetriebnah...

Page 3: ...d Bescherming tegen Legionella Bij gevaar voor hogere Legionella concentraties maatregelen voor thermische desinfectie voorzien volgens DVGW werkblad W 551 Bijzondere inachtneming bij installaties voo...

Page 4: ...n thermique prendre des pr cautions suivant DVGW document W 551 Une attention particuli re est prendre en consid ration pour les personnes souffrant d une immunit d ficiente Instructions de mise en se...

Page 5: ...onella concentrations take measures in accordance with DVGW work sheet W 551 Pay particular attention to installations for persons with immune deficiencies Start up information Schell shower fittings...

Page 6: ...a W 551 de las directrices DVGW Poner especial cuidado al realizar instalaciones para personas que sufran alg n tipo de inmunodeficiencia Indicaciones para la puesta en servicio Las grifer as Schell p...

Page 7: ...on SCHELL splash proof adhesive flange item no 01 857 00 99 prot ge la protects fittings against moisture penetration Accesorios para tabiquer a ligera Brida adhesiva SCHELL antisalpicaduras referenci...

Page 8: ...de eau chaude 1 0 bar Changer les cotes d installation pour les endroits utilis s par des enfants Pour handicap s pr voir de la place pour pouvoir manoeuvrer Douches dans le secteur de soin pr voir su...

Page 9: ...ar suficiente espacio en las duchas para personas en silla de ruedas Instalar suficientes agarraderas en las duchas para personas ancianas o discapacitadas G E Model WB SC V Hot water side blocked Flu...

Page 10: ...bserve wall installation depth Front edge of tiles Tener en cuenta la profundidad del empotraje Canto delantero azulejos D O F G E Masterbox montieren Masterbox in Montagemodul nach beiliegender Anlei...

Page 11: ...r For dry construction attach adhesive flange Accessory 01 857 00 99 Attach adhesive tape flush with the wall to clean dry master box Construcci n en seco montar brida de encolado Accesorio 01 857 00...

Page 12: ...90 302 15 00 A 11 16 SCHELL GmbH Co KG Armaturentechnologie Raiffeisenstra e 31 57462 Olpe Germany Telefon 49 2761 892 0 Telefax 49 2761 892 199 info schell eu www schell eu...

Reviews: