Scheiber 41.70509.01 User'S Manual And Troubleshooting Manual Download Page 4

Domotique embarquée

Embedded home automation

P.4

Domotique embarquée

Embedded home automation

BLOC 9

REFERENCE

41.70509.01

POWER SUPPLY

8-32 V DC up to 16 mm2

DETAILS AND FEATURES OF THE INPUTS

- 2 x CAN connectors type 6-way Micro-Fit

- 1 x LIN connector type 4-way Micro-Fit

DETAILS AND FEATURES OF THE OUTPUTS

- 6 adjustable power outputs in current from 3 to 25A.
- 2 x connectors 6-way in 6mm² max.

BYPASS FUSE (SUPPLIED)

15A (blue) 25A (brown)

Check that the cable section is sufficient depending on the size of 

the fuse used

LIN BUS

To manage up to 6 IBS sensor

CAN BUS

2 x connectors type 6-way Micro-Fit

ENVIRONMENTAL CONDITIONS

Indoor use

Altitude up to 2000m

Operating temperature: 0 to +50 °C

Relative humidity: 0 to 93% - non-condensing

Protection index: IP20

MOUNTING

Organize a panel cut-out 84,50 x 125,50 mm and 2 screws support

MOUNTING DISTANCE

138 mm

MECHANICAL

ABS Box UL94-V0

WEIGHT

0,19 Kg

STANDARDS

EN 60945

FIRMWARE VERSION

V7.21 or higher

DIMENSIONS (LxWxH)

150 x 95 x 69,6 mm (with socket mounted)

Technical characteristics

INPUT RATED VOLTAGE (VDC)

8-32 V DC

OUTPUT RATED VOLTAGE (VDC)

equal to the input voltage

SELF-CONSUMPTION

60 mA max.

MAXIMUM CURRENT PER OUTPUT

adjustable from 3 to 25A

MAXIMUM CUMULATIVE CURRENT

50A

Electrical characteristics

Description of the markings used

V

Volt

A

Ampere

       ou DC

Direct current

Summary of Contents for 41.70509.01

Page 1: ...Safety Warnings P 2 Accessories Associated references P 2 Equipment description P 3 Technical characteristics P 4 Electrical characteristics P 4 Description of the markings used P 4 Installation inst...

Page 2: ...oes heavy impact immediately contact a qualified person to ensure the device is working correctly WARNING Unpacking the equipment After unpacking the product make sure that it is complete and in good...

Page 3: ...the IBS measurements of battery status This network is provided through the CAN bus The various Blocs 9 in the network are differentiated via the MICROSWITCH which can be used to allocate anumber in t...

Page 4: ...tors type 6 way Micro Fit ENVIRONMENTAL CONDITIONS Indoor use Altitude up to 2000m Operating temperature 0 to 50 C Relative humidity 0 to 93 non condensing Protection index IP20 MOUNTING Organize a pa...

Page 5: ...r mounted Back view 55 3 23 5 14 3 95 84 50 150 138 125 50 3 20 S3 S3 S2 S2 S1 S1 Plug 1 Power connector Plug 2 S6 S6 S5 S5 S4 S4 X3 LIN BUS X2 CAN BUS X1 CAN BUS Bypass fuse bracket S1 S2 S3 S4 S5 S6...

Page 6: ...on with power on INPUT POWER SUPPLY Type of connection Cross section Clip 8mm connector 2 way de 6 16 mm OUTPUT Type of connection Cross section 2 x spring connectors 6 way 6 mm CAN BUS 2 x CAN connec...

Page 7: ...ng with the numbering on the BACK VIEW diagram Connect quick connectors on plugs 1 2 Connect the LIN bus to the IBS Connect the power plug 4 Connect either a connection cable with another device or a...

Page 8: ...ntrol keys ON OFF are used to control each of the outputs Bypass fuses are used to activate each function If your network has a NAVICOLOR type front panel check that The facade allows to control each...

Page 9: ...he fuse holder 3 In order to force the electrical function in the event of any malfunction of Bloc 9 you must install the Bypass fuse on the output concerned In the following example we force exit S3...

Page 10: ...the article 1641 and followings of the Civil Code Repairs and replacement of the equipment during the warranty period do not change terms or time of this warranty which is of 2 years Repairs and repl...

Page 11: ...2 Bellevue 85120 Saint Pierre du Chemin France Phone 33 0 2 51 51 73 21 sav scheiber fr www scheiber fr Question contact scheiber fr Problem sav scheiber fr L innovation fran aise depuis 1965...