Scheiber 41.70509.01 User'S Manual And Troubleshooting Manual Download Page 3

Domotique embarquée

Embedded home automation

P.3

Domotique embarquée

Embedded home automation

The power bloc can control up to 6 functions

With this box, it's possible to :

- Centralize power commands of 6 electrical functions.

- Provide electrical protection for each output.

- View the status of each system through status LED.

- Physically troubleshoot each order in the event of an electronic failure.

- Receive data from 6 IBS sensors (Intelligent Battery Sensor).

- Integrate into a MULTIBLOC compatible network, and therefore be controlled by equipment of the type:

 

• NAVICOLOR display.

 

• WIFI server.

 

• Multiplexed switch module.

 

A forced operation of each output is possible using a bypass fuse (2 fuses are supplied : 15A et 25A).

The 6 power outputs are adjustable from 3 to 25A and can control 12/24 DC networks like:

- interior lights,

- navigation instruments,

- navigation lights,

- the pumps,

- comfort devices,

- etc, ...
Several modules (Bloc 9 can be installed side by side depending on the number of functions to be controlled.

Integration in a Multibloc Network

One or more Blocs 9 can be integrated in a MULTIBLOC network. A NAVICOLOR display can then be used to:

- Configure the Bloc 9 outputs

- Control the outputs

- Read the output status

- Read the IBS measurements of battery status.

This network is provided through the CAN bus.

The various Blocs 9 in the network are differentiated via the MICROSWITCH which can be used to allocate anumber in the network.

Additional function of Bloc 9 when integrated into a Multibloc network:

Fuel transfer

Associated with a Bloc 7 and a Navicolor, Bloc 9 allows operation of pumps to make fuel transfers form one tank to another one directly 

from the touch screen.

Equipment description

LED Status

One LED per function indicates the status of the system:
- LED off: the circuit is inactive.

- LED on: the circuit is active.

Troubleshooting

The Bloc 9 has 6 fuse holders (for Mini Blade Fuse) to install the bypass for each circuit.

This solution allows each output to be overridden if there is a major failure of 

the electronic system.

Electrical protection

The Bloc 9 provides electrical protection for your systems:
- Rating adjustable from 3 to 25 A according to your needs

- Reverse polarity protection (+/- battery inversion)

- Current surge protection.

Management of IBS sensors

The bloc 9 can manage up to 6 IBS which can 

transmit the following battery information:
- Voltage
- Incoming and outgoing current
- Charge and discharge current
- Battery temperature
- Residual capacity
- Ageing.
The IBS are connected to the bloc 9 through the LIN 

bus. Measurements are read and alerts configured 

through a NAVICOLOR display.

Summary of Contents for 41.70509.01

Page 1: ...Safety Warnings P 2 Accessories Associated references P 2 Equipment description P 3 Technical characteristics P 4 Electrical characteristics P 4 Description of the markings used P 4 Installation inst...

Page 2: ...oes heavy impact immediately contact a qualified person to ensure the device is working correctly WARNING Unpacking the equipment After unpacking the product make sure that it is complete and in good...

Page 3: ...the IBS measurements of battery status This network is provided through the CAN bus The various Blocs 9 in the network are differentiated via the MICROSWITCH which can be used to allocate anumber in t...

Page 4: ...tors type 6 way Micro Fit ENVIRONMENTAL CONDITIONS Indoor use Altitude up to 2000m Operating temperature 0 to 50 C Relative humidity 0 to 93 non condensing Protection index IP20 MOUNTING Organize a pa...

Page 5: ...r mounted Back view 55 3 23 5 14 3 95 84 50 150 138 125 50 3 20 S3 S3 S2 S2 S1 S1 Plug 1 Power connector Plug 2 S6 S6 S5 S5 S4 S4 X3 LIN BUS X2 CAN BUS X1 CAN BUS Bypass fuse bracket S1 S2 S3 S4 S5 S6...

Page 6: ...on with power on INPUT POWER SUPPLY Type of connection Cross section Clip 8mm connector 2 way de 6 16 mm OUTPUT Type of connection Cross section 2 x spring connectors 6 way 6 mm CAN BUS 2 x CAN connec...

Page 7: ...ng with the numbering on the BACK VIEW diagram Connect quick connectors on plugs 1 2 Connect the LIN bus to the IBS Connect the power plug 4 Connect either a connection cable with another device or a...

Page 8: ...ntrol keys ON OFF are used to control each of the outputs Bypass fuses are used to activate each function If your network has a NAVICOLOR type front panel check that The facade allows to control each...

Page 9: ...he fuse holder 3 In order to force the electrical function in the event of any malfunction of Bloc 9 you must install the Bypass fuse on the output concerned In the following example we force exit S3...

Page 10: ...the article 1641 and followings of the Civil Code Repairs and replacement of the equipment during the warranty period do not change terms or time of this warranty which is of 2 years Repairs and repl...

Page 11: ...2 Bellevue 85120 Saint Pierre du Chemin France Phone 33 0 2 51 51 73 21 sav scheiber fr www scheiber fr Question contact scheiber fr Problem sav scheiber fr L innovation fran aise depuis 1965...

Reviews: