Operating and Installation Overvoltage Protection OVP 01 A
8
Issued: 20.12.2011
822.221 BA / EN
2.3 Electrical connection
Connect the overvoltage protection in the following sequence (please refer
to the block diagram and the view in the instruction manual):
1. Disconnect vehicle from the 230-V-mains current.
2. Disconnect 230 V mains plug from the electoblock EBL ...
3. Plug this 230 V mains plug into the overvoltage protection OVP 01 A at
“Mains”.
4. Connect the supplied mains extension cable into output 1 of the overvol-
tage protection OVP 01 A.
5. Insert the other end of this cable into the mains input of the electroblock
unit.
Devices with a two-pin earthed plug have to be modified. For the modifica-
tion, a IEC connector for cable mounting is available. You can order it from
Fa. Schaudt with the article.-no. 143.511.
Fig. 4
Kaltgerätestecker Art.-Nr. 143.511
Y
DANGER!
230 V unit carrying mains voltage.
Risk of fatal injury as a result of electric shock or fire:
F
Only qualified electricians are permitted to make this modification.
6. If necessary other consumers can be connected to output 2 of the over-
voltage protection.
Y
The block diagram/connection diagram are in the Appendix of this ma-
nual.
2.4 Storage - packaging - transport
Only transport and store the overvoltage protection if the packaging is suita-
ble and ambient conditions are dry.
The reproduction, translation and duplication of this manual, in whole or in
parts, is not permitted without written authorisation.
Connection sequence