12
Situation: 17.06.2005 831.300
SDT-0060-00EN
Instruction Manual Control and Switch Panel LT 500
8
Shutting down
Switch off the system if you are not going to use the motorhome for a lengthy
period (for example during the winter). The separation of the batteries is
established using the control and switch panel. In doing so, the living area bat-
tery is switched off electrically. There is still a closed circuit current of
approx. 4.5 mA. The shut down system requires approx. 4 Ah a month.
Shutting down the system
for up to 6 months
Fully charge up the living area battery before shutting down the system. The
living area battery is then protected against total discharge. This applies only
if the battery is intact. Follow the instructions of the battery manufacturer.
Switching off the system
1. Switch off the 12 V main switch on the control and switch panel.
2. Press the left side of the battery switch (living area battery) for more than
10 seconds. The entire scale display flashes twice briefly for confirmation.
Shutting down the system
for more than 6 months
Fully charge up the living area battery and remove the clamps on the battery
poles. Carry out the following work steps in the sequence mentioned below.
The battery alarm is then no longer active.
Disconnecting the living
area battery from the 12 V
power supply
Carry out the following work steps in the correct sequence:
1. Switch off the 12 V main switch on the control and switch panel.
2. Press the left side of the battery switch (living area battery) for more than
10 seconds. The entire scale display flashes twice briefly for confirmation.
3. Remove the clamps from the battery poles.
W
For other shutdown tasks, see the instruction manual for the Electrobloc.