Instruction Manual Control and Switch Panel LT 500

The control and switch panel can only be switched on if the living area battery 
voltage is above 11.0 V. If the living area battery voltage is insufficient, the 
12 V indicator lamp and the "V" symbol flash.

5.2

Switching the power supply for the pump on and off

12 V main switch/

pump switch

„

Press the right side of the switch briefly:
The pump can be switched on. The yellow indicator lamp lights up.

„

Press the right side of the switch again briefly:
The pump cannot be switched on. The yellow indicator lamp does not light 
up.

5.3

230 V mains indicator

230 V indicator lamp

The yellow 230 V indicator lamp lights if the input of the Electrobloc is live.

The yellow 230 V indicator lamp flashes if the vehicle's engine is started and 
if at the same time the input of the Electrobloc is live.

5.4

Checking the battery capacity and charging current 
of the living area battery

Battery switch

„

Press the left side of the battery switch once briefly:
The battery capacity is indicated on the 

"%"

 scale in 16 levels from 0 to 

100

%

. The illuminated scale points indicate the critical zone in red, the 

normal range is green.

„

Press the left side of the battery switch twice briefly:
The charging/discharge current is indicated on the 

"A"

 scale in 16 levels 

from 0 to 30 A.

The scale points light up in green: The charging current is displayed or 0 A.
The scale points light up in red: The discharge current is displayed.

The display shows all types of battery voltage:

P

Via the charger module of the 230 V mains

P

Via the cut-off relay of the alternator while driving

P

Via a solar charge regulator connected to the system

W

Switch off the 12 V main switch when you leave the vehicle. This pre-
vents the living area battery from unnecessarily discharging.

W

When the pump's power supply is switched off, the water tap can be 
opened without the pump starting (for example for draining the water 
pipes).

Summary of Contents for LT 500

Page 1: ...ual Control and Switch Panel LT 500 Instruction manual Control and switch panel LT 500 Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 3 4 Electrical data 4 5 Operation 4 6 Starting up 11 7 Maintenance 11 8 Shutting down 12 9 Technical faults possible causes and remedies 13 10 Customer service 13 11 Circuit diagram for specialist workshop only 14 12 Faul...

Page 2: ...ction manual must be followed Any technical faults affecting the safety of persons or of the control and switch panel must be dealt with immediately by qualified personnel W Failure to comply with this sign may lead to the endangerment of per sons W Failure to comply with this sign may damage the device or the connected consumers W This sign indicates recommendations or special features W The elec...

Page 3: ...green 2 12 V main switch pump switch 3 Indicator lamp for pump power supply yellow 4 Indicator LEDs tank level charging and discharge current battery voltage 5 Percentage scale display battery capacity tank level 6 230 V indicator lamp yellow 7 Indicator lamp for waste water tank heater yellow 8 Switch for tank level waste water tank heater 9 Unclear value warning lamp red 10 Battery switch 11 Cha...

Page 4: ...Switching the 12 V power supply for the living area on and off 12 V main switch pump switch The 12 V main switch pump switch turns all consumers on and off Exceptions P Frost protection valve P Heater P Step P Gas alarm waste water valve P Circuits 4 and 5 P Waste water tank heater P Pull down bed P Awning light P Awning P Satellite antenna P Compressor or AES refrigerator Press the left side of t...

Page 5: ...5 4 Checking the battery capacity and charging current of the living area battery Battery switch Press the left side of the battery switch once briefly The battery capacity is indicated on the scale in 16 levels from 0 to 100 The illuminated scale points indicate the critical zone in red the normal range is green Press the left side of the battery switch twice briefly The charging discharge curren...

Page 6: ...isplayed by the control and switch panel These values only apply to lead gel batteries in use not to off load voltage 1 depending on the current load Battery voltage Description Less than 10 5 V P Risk of total discharge P The battery monitor switches off all consumers apart from the frost protection valve 11 V or more The 12 V power supply can be switched on using the main switch 10 5 V to 12 V P...

Page 7: ...g charge or if the capacity of a battery has fallen below 15 Connect the motorhome to the 230 V power supply The batteries are charged 5 6 Indication of the maximum possible battery capacity The maximum battery capacity of the living area battery can be indicated but it cannot be set The maximum battery capacity is displayed in of the nom inal capacity The preset value of 80 26 indicator LEDs ligh...

Page 8: ...e g in the event of retrofitting a battery within the range of 60 Ah to 220 Ah Display principle The number of illuminated indicator LEDs indicates the set nominal capacity 60 Ah No indicator LED lights up 220 Ah All indicator LEDs light up In addition to the minimum capacity of 60 Ah 2 indicator LEDs light up for eve ry additional 10 Ah Example If 12 indicator LEDs light up that means 60 Ah 6 x 1...

Page 9: ...to fall so low that the automatic disconnector is triggered it is essential to switch off all consumers that are not required You may be able to switch the 12 V power supply back on for a short time Press the left side of the 12 V main switch The 12 V power supply is switched on If the battery voltage remains below 11 0 V you cannot switch the 12 V power supply back on If an attempt is made to swi...

Page 10: ... more information see section 5 5 as well as the instruction manual of the Electrobloc The control and switch panel can only be switched on if the living area battery voltage is above 11 0 V If the voltage is insufficient the 12 V indicator lamp and the V symbol flash if an attempt is made to switch on the control and switch panel 5 12 2 Battery capacity alarm If the residual capacity of the livin...

Page 11: ...tery immediately after start up Do not connect the vehicle to the 230 V mains do not start the engine and do not switch on any consumers until the off load voltage of the battery has been checked After an off load time of maximum 6 months the battery voltage should be above 12 7 V if the battery was fully charged before shut down If the voltage is below 12 0 V then the battery might be defective a...

Page 12: ...facturer Switching off the system 1 Switch off the 12 V main switch on the control and switch panel 2 Press the left side of the battery switch living area battery for more than 10 seconds The entire scale display flashes twice briefly for confirmation Shutting down the system for more than 6 months Fully charge up the living area battery and remove the clamps on the battery poles Carry out the fo...

Page 13: ...sk Schaudt GmbH for a suitable pro tective bag Fill in and enclose the fault report see section 12 Send it to the addressee delivered free Disposal instruction When the product service life is over dispose of the device in accordance with the applicable regulations Fault Possible cause Remedy 12 V power supply does not work 12 V main switch turned off Switch on the 12 V main switch System shut dow...

Page 14: ...2 3 4 2 3 4 3 1 2 3 1 2 4 1 4 4 1 4 5 Base water tank 5 Base waste water tank 6 Not assigned X3 block 1 Lumberg 2 5 MSFQ 0 10 x X4 block 2 Lumberg 2 5 MSFWQ 0 12 x to Electrobloc 1 D 1 Main switch relay 1 Off 2 Pump 2 Main switch relay 1 On 3 Waste water tank heater 3 Main switch relay 2 Off 4 Frost protection valve 4 Main switch relay 2 On 5 Not assigned 5 Mains signal 6 Not assigned 6 Shunt cons...

Page 15: ...e please return the defective device together with the completed fault report Software version number do not forget to state it There is the following defect please tick Other remarks Device type Type no LT 500 Malfunction of which type Faultydisplayof the device Tank Voltage Others which Constant fault Temporary fault loose con tact ...

Page 16: ...16 Situation 17 06 2005 831 300 SDT 0060 00EN Instruction Manual Control and Switch Panel LT 500 ...

Reviews: