Operating Instructions Operator and control panel LT 45X
10
Date: 29.05.2020
9310330 BA / EN
3.7 Troubleshooting and remedies
3.7.1 Alarms
Y
ATTENTION!
Total discharge results in damage to the leisure area battery:
F
A low battery charge, indicated by low voltage, must be prevented.
F
Check the voltage regularly (see Section 3.5)
Y
It is best to carry out checks in the morning before 12V consumers are
switched on.
Alarm
Possible cause
Remedy
When the system is swit-
ched off:
-- Voltage of the leisure
area battery has fallen
below 11.4V.
With system switched on
Switch off all 12V consu-
mers.
With system switched on
and check of leisure area
battery voltage:
-- Voltage of the leisure
area battery has fallen
below 11.0V.
Applicable for both cases:
Risk of total discharge of
the leisure battery.
Charge the battery:
-- Start engine
or
-- connect to 230V power
supply
3.7.2 Faults
The majority of power supply system faults are caused by blown fuses (refer
to the instruction manual for the relevant EBL ... / CSV ... power supply for
information on voltage distribution and .
Please contact our customer service team if you cannot rectify a fault using
the following table.
If this is not possible (such as when you are abroad), you can have the elec-
trical vehicle system repaired at a specialist workshop. In this case, you
must ensure that the warranty is not invalidated by incorrect repairs being
carried out. Schaudt GmbH will not accept any liability for damage resulting
from such repairs.
Fault
Possible cause
Remedy
12V supply does not
function (or some areas
t
d)
12V main switch is
switched off.
12V main switch must be
switched on.
(
are not powered).
Fuse blown.
Refer to the operating
manual for the EBL...
power supply . .
12V indicator LED (green)
does not light up.
12V main switch is
switched off.
12V main switch must be
switched on.
g
p
Leisure area battery not
charged.
Charge the leisure area
battery.
Fuse blown.
Refer to the operating
manual for the EBL... .
Flat vehicle fuses