Instruction Manual for Electroblock EBL 30 / EBL 30 with OVP
5
Date: 15.10.2018
8110305 BA / EN
3.3 Faults
A flat battery or defective fuse is the cause of most faults in the power sup-
ply system.
If the battery is discharged, consumers can always be powered by starting
the engine of the base vehicle.
Please contact our customer service address if you cannot rectify the fault
using the following table.
If this is not possible, e.g. if you are abroad, you can have the electroblock
repaired at a specialist workshop. In this case, you must ensure that the
warranty is not invalidated by incorrect repairs being carried out. Schaudt
GmbH will not accept any liability for damage resulting from such repairs.
Fault
Possible cause
Remedy
Leisure area battery is not
h
d d i
230V
No mains voltage
Switch on the automatic
i
i b
k i h
hi
y
charged during 230V ope-
ration (battery voltage
g
circuit breaker in the vehi-
cle; check the mains vol-
ration (battery voltage
constantly below 13.3 V)
cle; check the mains vol-
tage
y
)
Too many consumers are
switched on
Switch off any consumers
not required
Defective electroblock
Contact customer service
Living area battery is over-
charged during 230V ope-
ration (battery voltage
constantly above 14.5 V)
Defective electroblock
Contact customer service
Starter battery is not char-
d d i
230V
No mains voltage
Switch on the automatic
i
i b
k i h
hi
y
ged during 230V opera-
tion (battery voltage con-
g
circuit breaker in the vehi-
cle; check the mains vol-
tion (battery voltage con-
stantly below 13.0 V)
cle; check the mains vol-
tage
y
)
Too many consumers are
switched on
Switch off any consumers
not required
Defective electroblock
Contact customer service
Leisure battery is not
charged during mobile
ti
(b tt
lt
Defective alternator
Have the alternator chek-
ked
g
g
operation (battery voltage
below 13.0 V)
No voltage on D+ input
Have the fuse and cabling
checked
Defective electroblock
Contact customer service
The leisure battery is
overcharged during mo-
bile operation (battery vol-
tage permanently above
14.3 V)
Defective alternator
Have the alternator chek-
ked
The refrigerator does not
work during mobile opera-
tion
No power supply to the re-
frigerator
Have the fuse (20A of sup-
ply; possibly 2A of the D+
signal) and wiring checked
Defective electroblock
Contact customer service
Defective refrigerator
Havetherefrigeratorchek-
ked
Solar charging does not
Solar charge regulator not Plug in solar charge regu-
Solar charging does not
work
Solar charge regulator not
plugged in
Plug in solar charge regu
lator
Defective fuse or cabling
Have the fuse and cabling
checked
Solar charge regulator de-
fective
Have solar charge regula-
tor checked
Flat vehicle fuses
Discharged battery --
start motor