Instruction Manual for Electrobloc EBL 99 K / EBL 99 K with OVP
6
Date: 20.01.2010
811.419 BA / EN
Fault
Remedy
Possible cause
Solar charging does not
Solar charge regulator
Plug in solar charge
Solar charging does not
work
Solar charge regulator
not plugged in
Plug in solar charge
regulator
Defective fuse or wiring
Check fuse and wiring
Solar charge regulator
defective
Check solar charge
regulator
12V supply does not
work in the living area
12V main switch for the
living area battery is
12V main switch for the
living area battery must be
work in the living area
living area battery is
switched off
living area battery must be
switched on
Not all plugs or fuses are
plugged into the
plug in all plugs and fuses
(correct values!) to the
plugged into the
electrobloc
(correct values!) to the
electrobloc
Defective fuse or wiring
Check fuse and wiring
Defective fuse or wiring
Check fuse and wiring
Defective electrobloc
Contact the customer
service department
Y
If the device becomes too hot due to excessive ambient temperature or
lack of ventilation, the charging current is automatically reduced. Always
prevent the device from overheating nevertheless.
Y
If the automatic shutdown mechanism of the battery monitor is triggered,
fully charge the living area battery.
3.4 Closing down the system
The battery is isolated by switching off the battery cut-off switch.
Y
ATTENTION!
Total discharge.
Damage to the living area battery:
F
Fully charge the living area battery before and after closing down the
system. (Connect vehicle to the mains with an 80Ah battery at least
12 hours and with a 160Ah battery at least 24 hours).
Disconnect the living area battery from the 12V power supply if the motor-
home is not used for a longer period (during the winter for example).
³
Fully charge the living area battery before closing down the system.
³
Switch off from the main switch of the IT ... /LT... control and switch pa-
nel.
³
Turn the battery cut-off switch (see Fig. 3, Pos. 12) to ”Off”. The following
connections are isolated from the living area battery:
F
All 12V consumers
F
Frost protection valve
F
Control and switch panel
The living area battery is then protected against total discharge. This only
applies if the battery is intact. Follow the battery manufacturer’s instructions.
Y
If the living area battery is isolated from the electrobloc with the battery
cut-off, the frost protection valve of the combination heating opens. A
loss of water is possible (see operating instructions of the combination
heating).
Closing down