Change administrator pass

code

The factory-set 

administrator passcode

 is 

999999

. It allows the user to change the access codes for all four channels of the code

-keypad

. To 

change the administrator pass

code

, please proceed as follows:

1.

Press the 

B button

 on the code-keypad 

once

 and then type in the 

currently valid administrator passcode

 (999999

 

for factory settings). 

-> You'll 

hear two beeps and the LED on the code-keypad lights up red!

2.

Now 

press button 1 once

 and then 

button B once

.

 -> You

'

ll hear two beeps again, the LED flashes once and then

 

lights up red again.

3.

Now enter your new, 

6-digit administrator passcode

 and then 

press the B button once

.

 -> The LED flashes once

 

and then lights up red again.

4.

Now type in the 

6-digit administrator passcode again

 and then 

press the B button again

 -> 

You'll hear a beep, the

 

LED flashes once and then 

goes out. The new administrator passcode is now saved.

Change the access code

The factory-set access codes are as follows

:

Channel

 

1: 

111111

 

Channel 2: 

222222

 

Channel 3: 

333333

 

Channel 4: 

444444

To change an access code, please proceed as follows:

1.

Press the B key once

 and then enter the 

administrator passcode

.

 -> You'll hear a beep, the LED on the code-keypad

 

flashes once and then lights 

up red.

2.

Now 

press button 1 once

 (for channel 1) and then 

button A once

.

 -> You'll hear a beep, the LED on the code-keypad flashes once and then lights 

up red.

3.

Now enter your 

new 6-digit access code

 and then 

press button B once

.

 -> The LED on the code-keypad flashes

 

once and then lights up red.

4.

Enter the new 

6-digit access code again

 and press the 

B button once again

-> You'll hear a beep, the LED flashes

 

once and then goes out. The 

new access code is now saved.

Simplified EU Declaration of Conformity (CE)

Schartec hereby declares that the code-keypad UKP-4 complies with Directive 2014/53/EU. The full text of the EU Declaration 

of Conformity is available at the following Internet address: www.schartec.de/en

Information about battery regulation

As a dealer for the distribution of electronic, battery-operated devices, we are obliged by law to inform our customers about 

the following:

Electrical and electronic devices, as well as batteries, must not be disposed of as household or residual waste, but must be 

delivered in the appropriate acceptance and collection points.

The complete version of the battery law can be found here:

http://www.gesetze-im-internet.de/bundesrecht/battg/gesamt.pdf

5

SCHARTEC

a trademark of bau-shop-24 GmbH 

Fritz-Müller-Strasse 119

73730 Esslingen

Germany

WEEE Reg. Nr.: DE90317979

BattG Reg. Nr.: 21008776

IMPORTANT! 

The radio code switch UKP-4 has 4 channels and can therefore operate up to 4 different door drives. To program another channel, 

please carry out the same steps.

Therefore 1 stands for channel 1, 2 for channel 2, 3 for channel 3, and 4 for channel 4

ATTENTION!

 The door travel can be accidentally triggered when the radio code-keypad is being taught in.