20
2019-05-24 / V1.0
Installation
Contactors C137/C163/C164/C165 – Installation and Maintenance Instructions
DIN rail mounting
The contactor can also be installed by means of DIN rail
mounting. DIN rail mounting sets can be ordered from
Schaltbau GmbH.
The installation is possible either at the rear side or at
the bottom side of the contactor.
Installation on the rear side
X
Fix the DIN rail adapter (4) with 4 cylinder screws
M3 x 5 (6) and 4 washers (5) on the mounting plate
(3). Torque for the cylinder screws: 0.6 Nm
X
Place the mounting plate (3) at the rear side of the
contactor an fix it from the front side with 4 cylin-
der screws (1) and 4 washers (2).
X
Tighten the cylinder screws (1) with the deter-
mined torque according to the table:
Series
Cylinder screws (1)
Torque
C137
M3 x 8
0.6 Nm
C163
M5 x 10
1.4 Nm
C164
C165
X
Attach the installed contactor with the DIN rail
adapter (4) to the DIN rail (7).
1
2
3
4
5
6
7
Fig. 20: DIN rail mounting: Installation on the rear side (the figure shows C163, the procedure for C137, C164 and C165 is the same)