Schaller SW1 User Manual Download Page 10

 page 10 

 

version 1.1_n 

Technical data 

 

Measurement 

Measuring range    /  Resolution  / Accuracy 

Rel. air humidity:

  0 to 100% rh 

/ 0.1% 

Calibration: 

 

10 to 90%  

 

         / ± 2% rh (at 25°C/50%rh)  

 

Temperature °C:

  -10 to +60°C 

 

/ 0.1°C 

         / ± 0.3°C (at 25°C)

 

Temperature °F:

 

 14 to 140°F 

 

/ 0.3°F 

         / ± 0.5°F (at 77°F) 

 
 
Operating temperature range:

 

-10°C to 60°C / 14 to 140°F 

Storage temperature:

 

-20°C to 60°C / -4 to 140°F 

Temperature compensation:

 

automatic 

Data storage: 

approx. 10,000 measuring values 

Menu languages:

 

 English, German, French, Italian, 
Spanish, Russian 

Power supply:

 

4 pcs. of 1.5Volt AA Alkaline batteries 

Life time battery:

 

mould warning function: approx. 12  

 

months  

 

ventilation monitor: approx. 1300  

 

measurements 

Auto Off time:

 

after approx. 4 minutes 

Power consumption:

 

30 mA (with display lighting) 

Display:

 

128 x 64 matrix display, 

 

with LED backlight 

Dimensions housing: 

166 x 64 x 30 mm

 

Weight

 

210g (with batteries) 

Protection class:

 

IP 40 

Scope of supply:

  

humimeter SW1, 4 x 1.5Volt AA Alkaline 
batteries, manual 

 

 

Summary of Contents for SW1

Page 1: ...User manual mould and air guard humimeter SW1 to prevent from health threats version 1 1_en Schaller GmbH 2017 ...

Page 2: ...Preventing and avoiding mould Mount a wall hook on a position with increased potential of mould e g outer wall and position the humimeter SW1 device on the hook Switch on the instrument by pressing the button for 3 seconds Select the calibration curve Risk of mould using the arrow keys or The device switches on regularly and checks the level of risk In case of a high or very high risk of mould an ...

Page 3: ...inition of calibration curves Risk of mould The calibration curve risk of mould clearly evaluates the risk grouped into 5 risk levels The risk levels are related directly to the relative air humidity calibration curve description unit measuring range risk of mould risk of mould No up to Very high abs humidity absolute air humidity g m 0 to 130 g m3 rel humidity relative air humidity rh 0 to 100 To...

Page 4: ...s saturated with water vapour for half of its value 100 relative humidity means that the air is totally saturated When the air has more than 100 of relative humidity the excessive moisture would condense or form fog Operating the instrument Switching on Press for three seconds Changing the calibration curve or Menu Switch on the instrument pressing the key and immediately during showing the start ...

Page 5: ...s the key to reach the store menu For saving a measuring value or activating an automatic log press the button For completing the AutoLog switch on the device if necessary and press the button If you want to add additional data please press the button Additional data can also be entered on the PC subsequently For returning to the normal use all menu items have to be reset Unlocking by entering the...

Page 6: ...s Clear Logs Print Logs Last Logs All Logs Clear Logs Send Logs Manual Logs Auto Logs Clear Logs Options Date Time Interval Language Unlock C F DataLog Time Userlevel BL On Time Auto Off Time Materialcalib Password Reset Status Keypad symbols Measuring window Rolling menu Power ON OFF Switch upper Switch lower Save Hold Autolog Watch saved data Enter supplier s data Menu Enter Switch upper Switch ...

Page 7: ...version 1 1_n page 7 Design of the device batteries slot flipside display of measuring value calibration curve ON button selection of calibration curve warning light wall holder ...

Page 8: ...e measuring instrument and the material to measure resp the air Care instructions Do not drop the instrument or expose it to excessive temperatures The instrument is not waterproof Do not immerse the sensor in liquid The intervals for checking the instrument depend on your operational demands and the required level of accuracy In general the drift of the sensor according to the degree of use const...

Page 9: ...tteries Press with your finger onto the arrow of the battery cap and pull it back Remove the empty batteries Put four new 1 5 Volt AA Alkaline batteries in the device Make sure that the position of the battery poles is correct Press down the batteries and close the cap If the battery symbol appears in the measuring window resp if a critical charge of battery is shown in the status the batteries ha...

Page 10: ...ation automatic Data storage approx 10 000 measuring values Menu languages English German French Italian Spanish Russian Power supply 4 pcs of 1 5Volt AA Alkaline batteries Life time battery mould warning function approx 12 months ventilation monitor approx 1300 measurements Auto Off time after approx 4 minutes Power consumption 30 mA with display lighting Display 128 x 64 matrix display with LED ...

Page 11: ...o too short conditioning time To demonstrate the importance of temperature adjustment the table below shows measuring errors due to a temperature difference of only 1 C 1 8 F between the measuring instrument and the substance to be measured at different ambient temperatures 10 C 50 F 20 C 68 F 30 C 86 F 10 r F 0 7 0 6 0 6 50 r F 3 5 3 2 3 0 90 r F 6 3 5 7 5 4 At room temperature 20 C 68 F and an a...

Page 12: ...is blinking Ventilation monitor Calibration curve Absolute humidity If the measuring value INDOORS is HIGHER you can ventilate INDOORS OUTDOORS VENTILATE If the measuring value INDOORS is LOWER you may NOT ventilate Climate monitor Calibration curve relative humidity Ideal interior air humidity 40 60 A too high or too low value is felt as unpleasant and may cause health risks ...

Reviews: