Operating voltage
230V 50/60Hz 10 %
Power consumption
approx. 0.66 W
Wind measuring range
10-70 km/h
Wind switching hysteresis
25 %
Wind response time
15s (dynamically)
Sun measuring range
Light intensity: 20000Lux - 100000Lux / Twilight: 1Lux - 70Lux
Sun switching hysteresis
Light intensity: 40 % / Twilight: 20%
Sun response time
10 min (1...60min programmable)
Motor run time
90s (1...240s programmable)
Relay switching dead time
0.6s
Sensor supply voltage
3.3V DC (PELV)
Ambient temperature
-10°C to +45°C
Installation orientation
Any
RAL colour
Grey 7035 / Green 6029
SMS 2 / SMS U2 technical data
Order data
Relay output
2 NO contacts 4A/250V AC
Auto-reverse time
0,7s (0.1 to 2.4s programmable)
AC Connections
Socket terminals with captive screws M3
- Clamping range
0.5 mm² - 2.5 mm²
- Strip length
6.5 mm - 7.0 mm
- Screwing torque
0.50 Nm
PELV Connections
Socket terminals with captive screws M2
- Clamping range
0.25 mm² - 1.5 mm²
- Strip length
6.0 mm - 6.5 mm
- Screwing torque
0.20 Nm
Dimensions
43 x 43 x 18.5mm³
SMS U2:
Part no.
EAN
Type
Designation
SMSU29
SMS U2
Sensor-controlled motor control (wind/light), 230V AC (FMD)
SMS209
SMS 2
Sensor-controlled motor control (wind/light), 230V AC (REB)
SW4000
SW 4
Wind sensor with articular mount
SL2000
SL 2
Light sensor with clip bracket
201
9-
06
-01
Sensor type
Reed contact pulse generator
Feed line
max. 50m (at 2 x 0.25mm²)
Dimensions
ca. 85 x 125 x 250mm
3
Technical data SW 4
Sensor type
Phototransistor
Feed line
max. 50m (with 2 x 0.25mm²), screw connection: PG9
Protection class
IP65
Dimensions
ca. 65 x 20mm
3
Technical data SL 2
Relay output
2 NO contacts potential-free, 10A/250V AC
Auto-reverse time
0,7s (0.1 to 2.4s programmable)
Mounting
Snap-on mounting on 35mm top-hat rail according to EN 60715
Connection terminals
Cage clamp terminals with captive screws M3.5
Clamping range
0.5 mm² - 4.0 mm²
Strip length
6.0 mm - 6.5 mm
Screwing torque
0.80 Nm
Dimensions
18 x 88(45) x 58mm³
SMS 2: