Motor controllers
www.schalk.de
M
otor
con
tro
lle
rs
The local inputs „OPEN“ (A) or „CLOSE“ (Z) are edge-cont-
rolled and react with the falling edge.
A t
uv
=0.6s pause when switching between 14 and 24 serves
to protect the awning motor.
The automatic shading system can be completely deactiva-
ted for 5 hours by pressing the button (A or Z) for 5 seconds.
After this time has elapsed (or previously by pressing the
awning again), the automatic system is reactivated.
Info: Counter-rotation of the blinds must be deactivated!
Blind counter-rotation function (SMS 2 only):
Local inputs are level-controlled when the button is pressed
briefly and edge-controlled when the button is pressed long.
Countercurrent pulse (tg) is triggered during shading (see
running time diagram for sun) or by manual stop with A or Z.
Functional diagrams
Running time diagram „Sun
Example: light = 70000lx; twilight = 30lx (only SMS 2); t
LZ
= 240s (programmed)
t
an
= 10min (response time, user programmable); t
m
= 90s (motor run time, user programmable), blind auto-revers time (only
SMS 2) t
g
= 0,7s (adjustable)
Auto shading
function
deactivated
Illumination
light
Illumination trend
twilight
time [h]
(only SMS 2)
Twilight function
(only SMS 2)
counter-rotation function
(only SMS 2)