Installation, Mounting and Maintenance DISA-360

Z11/35 - 8

Construction subject to change.

No return possible!

20.10.2015

Version:

Checks

Prior to commissioning, the following items must be checked or

guaranteed:

During commissioning itself, the following items must be guar-

anteed:

Maintenance

For reasons of safety, the power supply and hydraulic circuit

must be disconnected prior to any maintenance activity. If the

unit was operated in heating mode, you have to wait until the

register has cooled down.

Folding down of the secondary air grille

The entire DISA-360 is equipped with a series of safety locks,

which allow the grille to be folded down via a rotating mecha-

nism on one of the profiles for safe execution of maintenance.

The secondary air grille is folded down as described below:

Clean them with an industrial vacuum cleaner or steam cleaner

or by spraying it with a non-aggressive cleaner.

- Hydraulic connections were tightened properly and exhib-

it no leaks.

- Connecting and fastening elements have been sufficiently

tightened.

- Adequate access for carrying out the maintenance activi-

ties has been provided.

- Use the on-site ventilation devices to ensure that no air re-

mains in the register and the water circuit.

- The connecting and fastening elements have been suffi-

ciently tightened.

- In heating mode, the temperature of the discharged sup-

ply air is not above 40°C.

- Open the safety locks.
- Fold the grille down.
- This makes the grille and the registers freely accessible

for cleaning purposes.

- After having carried out the maintenance work, the grille is

placed again in its original work position. Make sure that the

locks are engaged.

After these items have been taken care of,

the correct fastening of the device must be

When performing maintenance activities, it is rec-

ommended wearing personal protective equip-

ment, in order to avoid cuts and other injuries

produced by sharp and pointed parts.

1

2

Summary of Contents for DISA-360

Page 1: ...Ferdinand Schad KG Steigstra e 25 27 D 78600 Kolbingen Telephone 49 0 74 63 980 0 Fax 49 0 74 63 980 200 info schako de www schako de Installation Mounting and Maintenance DISA 360...

Page 2: ...ered model 4 Function 4 Installation and commissioning 5 Operating conditions 5 Material reception 5 Transport lifting and handling 5 Storage 5 Installation 6 Mounting 6 Hydraulic connections 6 Connec...

Page 3: ...lacement of defec tive materials Recycling The inspection installation hydraulic connection and com missioning of the device must be carried out by qualified skilled personnel only in compliance with...

Page 4: ...ing or optionally 4 pipe system cooling and heating The registers consist of cop per pipes 12 mm in thickness aluminium ribs and a steel frame Grille 3 Possible designs perforated sheet grille made of...

Page 5: ...Foldable perforated sheet perforation 6 mm B Nozzle configuration B 592 total width 592 mm 592 total length 592 mm WS1 Water connection left H Connection horizontal AS1 Number of connecting pieces 1 c...

Page 6: ...void excessive tighten ing or twisting of the register connections Make sure that places that are intended as openings for air admission and air discharge are free of pipes electric ca bles crossbeams...

Page 7: ...ends on the select ed model Please follow the instructions enclosed with each model Adjustment of the air deflection blades To regulate the air flow ro tate the air deflection blades manually With blo...

Page 8: ...by spraying it with a non aggressive cleaner Hydraulic connections were tightened properly and exhib it no leaks Connecting and fastening elements have been sufficiently tightened Adequate access for...

Page 9: ...lean it by spraying it with water or compressed air or by evacua tion Please do not use any scouring agents for cleaning since these materials may impair or damage the DISA 360 gal vanised steel alumi...

Page 10: ...e nozzles at the primary air plenum box see drawing and the other end is con nected to the hose connection of a Pa meter The values read on the meter and the following formula can be used to to determ...

Page 11: ...or Install thermostat in a different place Clogging of the cooling heating register Clean the register in accordance with the maintenance instructions The unit is losing water Condensate in the regist...

Reviews: