Schaeffler Technologies
BA 67
23
12-seconds signal
(function FIL)
The 12-seconds signal triggers the function FIL. In total, 12,8 cm
3
of
lubricant is transported from the grease cartridge in 20 dispensing
processes per outlet. The total time for carrying out the function FIL
once is approx. 12 minutes. The operation is complete as soon as
lubricant emerges from the outlet. It may be necessary to carry out
the function FIL several times until lubricant emerges. If the empty
level is reached during function FIL, the outstanding delivery strokes
are continued once the cartridge has been replaced.
NOTICE
Air in the lubricant line can damage the lubrication point due to
insufficient lubrication. Bleed the lubricator every time it is
commissioned.
This function is required for:
■
initial operation
■
bleed the piston pumps.