LFp
LSp
LIp
Leq,t
Leq,T
Lpeak
LFmax
LFmin
LSmax
LSmin
LImax
LImin
SEL
E
Lex,8h
LAVG
TWA
DOSE
LN
Linst
When noise dose doubled, the added value of time weighting
average SPL
If time weighted SPL less than the value, it will not participate
in TWA, LAVG calculations
When noise dose is more that this value, the corresponding
instructor light will be lighted
F-weighted maximum SPL (sound pressure level) in 1 second
F-weighted maximum SPL in 1 second
I-weighted maximum SPL in 1 second
Short-time equivalent SPL. t is the average integral time,
which is determined by the set sampling interval. t is generally
less than 10s.
Equivalent-continuous SPL. T is the average integral time
which can be set casually from 1 second to 24 hours
Peak SPL
maximum sound pressure level, F-weighted
minimum sound pressure level, F-weighted
maximum sound pressure level, slow detector
minimum sound pressure level, slow detector
I-weighted maximum SPL
I-weighted minimum SPL
Sound exposure level
Personal sound exposure, expressed in Pa2h
equivalent SPL of 8 hours
Average SPL
Time-weighted average SPL
Noise dose, which is the percentage of time that a person is
exposed to noise that is potentially damaging to hearing. 100%
represents the noise exposure has exceeded the standard.
statistic SPL. N is an integer ranges from 1 ~ 99 and can be
casually chosen by the user
The instant value of time-weighted SPL