SCANTRONIC 9100 (3000)

SYSTEM SPECIFICATION

System capacity

16 zones plus Entry/Exit, PAB, 24 Hour, 
Auxiliary zone

Keypads

2 remote keypads maximum

Programming

16 programmable zones

User Codes

1 access code
1 engineer code

Communications

Plug on 9058 digital communicator
Plug on STU (Redcare)

Audible warning devices

Onboard sounder as standard
External bell/strobe
Internal sounder

Other facilities

Soak test
Double knock
Chime
Exterminator circuit
Part set
60 event alarm log

Written  By Paul Wright

Summary of Contents for 9100

Page 1: ...gramming 16 programmable zones User Codes 1 access code 1 engineer code Communications Plug on 9058 digital communicator Plug on STU Redcare Audible warning devices Onboard sounder as standard External bell strobe Internal sounder Other facilities Soak test Double knock Chime Exterminator circuit Part set 60 event alarm log Written By Paul Wright ...

Page 2: ...s The system has now set PART SETTING THE SYSTEM Press the number 1 Part Set square then ENTER followed by the code number The DAY LED will extinguish the PART SET LED will illuminate and the exit tone will start The system has part set correctly when the exit tone stops UNSETTING THE SYSTEM Enter the premises by the normal route The entry tone will start Proceed directly to the panel or Keypad an...

Page 3: ...er and the DAT LED will extinguish The exit tone will start Within 5 seconds press the omit square followed by the zone number to be omitted then press 0 will appear in the display Repeat this if other zones are to be omitted When all the required zones have been omitted leave by the normal exit route The system has set correctly when the exit tone stops Enter the code number to silence the sounde...

Page 4: ...e display and the fault LED will illuminate If the system is programmed for audible line fault develops in day mode When the system is programmed for silent line fault the L will appear in the display and the fault LED will illuminate but the sounder will not activate engineer visiting the premises or by the use of a remote reset keypad if fitted The monitoring station or ARC should not perform a ...

Page 5: ...PER LIGHT LIT TAMPER CIRCUIT ON ENTRY EXIT ZONE ENGINEER REQD AND ALARM LIGHT LIT ACTIVATION WAS ON ENTRY EXIT ZONE OLD SYSTEMS CONTAINING SMOKE DETECTOR AND ALARM LIGHT LIT AUX ALARM OPERATED NORMALLY AND TAMPER LIGHT LIT PA CIRCUIT TAMPER ENGINEER REQD CODE THREE TIMES AND TAMPER LIGHT LIT 24HR LOOP TAMPER ENGINEER REQD ZONE ENGINEER REQUIRED AND TAMPER LIGHT LIT PANEL BELL OR TAMPER LOOP DISPLA...

Reviews: