496368 Issue 1

3 of 12

Wiring

Figure 1. External SAB Bell/Strobe and Internal Speaker Connections

Notes:

1. SAB shown for negative applied. The connections shown in Figure 1 are
only an example of a typical SAB module. See the bell manufacture’s instruc-
tions supplied with individual units for more information.
2. Link tamper return to 0V if no external tamper is required.
3. Connect all bell wiring to control panel with exception of the trigger to the
siren or bell. The bell/siren will continue to ring from the on-board battery until
the final connections are made after initial power-up.

Programming

Programming Detectors

A series of six DIL switches on the control panel main printed-circuit board
enables each system to be identified by means of a different code, thereby
avoiding the possibility of interference from adjacent systems. The site code
is used by the control panel and all detector/transmitters in a particular
system. Select a site code and set the six DIL switches. Carefully note the
settings of the six site code DIL switches as this code is used when setting
each transmitter/detector.

4600

Summary of Contents for 4601

Page 1: ...ipment 4601 Long range and short range pendant transmitters 4602 Hand held PA 4603 Programmable transmitter 4604 Contact transmitter 4605 Short range dual channel transmitter 4608 PIR 4609 Smoke detector 7150 Viper radio vibration detector supplied by Weyrad Elec tronics ...

Page 2: ... Max 30VA Short circuit protection Outputs short circuit protected for indefinite periods by means of Polyswitches which will recover after removal of short circuit Reverse polarity protection Battery connections are reverse polarity protected for at least 5 minutes Battery back up Back up time panel only with fully charged battery typically 20 hours 12V Lead Acid battery typically 2 1AH Float cha...

Page 3: ...en or bell The bell siren will continue to ring from the on board battery until the final connections are made after initial power up Programming Programming Detectors A series of six DIL switches on the control panel main printed circuit board enables each system to be identified by means of a different code thereby avoiding the possibility of interference from adjacent systems The site code is u...

Page 4: ...e user code 1234 to silence the internal sounder The panel is now in DAY mode The walk test and other LEDs may be illuminated but please ignore them at this stage To Enter Programming Mode Make sure the Day LED is glowing before trying to enter programming mode 1 Press 0 then Enter 2 Key in the engineer access code default 7890 3 Open control panel cover to activate the lid tamper switch All panel...

Page 5: ...the values taken by each com mand The panel gives three short high pitched beeps if it accepts the values you enter If you enter an incorrect value the panel gives a longer lower pitched fault tone When you complete a command correctly the panel flashes all LEDs to show that it is ready for another command Note It is not necessary to program all the options Where a change has to be made to a parti...

Page 6: ...stant Night Mode 33 ENTER Any ENTER See note 3 OFF Remote Set 34 ENTER Any ENTER Zone 8 LED shows status ON First Zone Lockout 35 ENTER Any ENTER See note 4 ON Part Set Exit Timer 41 ENTER 1 ENTER 10 seconds 2 ENTER 20 seconds y 3 ENTER 40 seconds 4 ENTER 60 seconds 5 ENTER Continuous 6 ENTER Instant 1 5s bleep followed by 20s silent Bell Duration Timer 42 ENTER 1 ENTER 1 5 mins 2 ENTER 3 minutes ...

Page 7: ...Mode only affects entry exit zones that are also part set zones If the mode is ON part set entry exit zones become instant alarm zones rather than entry exit zones during part set mode only If the mode is OFF the part set entry exit zones are entry exit zones as normal This mode has no affect in the full set mode or on entry exit zones that are not part set zones 4 Unless Entry Route zones are inc...

Page 8: ... advise you to carry out a walk test 1 Key in 3 then Enter 2 Enter the user code default 1234 The Test LED glows steadily 3 Open or activate each zone in turn The appropriate zone LED glows as you activate the zone The panel gives a loud tone while the zone is open or activated When you close the zone the display shows the next open or activated zone or contin ues to display the last open or activ...

Page 9: ...isplays Low battery on zone detector Replace battery Jamming present on zone 4 Check for interfering radio signals Activate detector transmitter and enter user code twice If fault persists then call Scantronic product support Zone activated during exit time or during re arm period after an alarm Enter user code twice Tamper on zone active during exit time or during re arm period after an alarm Ent...

Page 10: ...witch turned on Low battery on remote setting transmitter Replace battery Zone indicated has been activated If the mains fails then the power LED flashes If the battery voltage is low then the power LED goes dark and the panel beeps every 30s When the battery voltage falls below 8V approx then the panel stops operating Fault Finding 4600 ...

Page 11: ...ad PA 1 3 Silence Bells User code Reset User code Change User Code 6 Enter existing code new code Enter Walk Test 3 Enter User code activate detectors Enter to end test On older units User code 3 Enter activate detectors Enter to end test Chime On Off 4 Enter User code From the 4605UK 55 Remote Setting Device Full Set Press top button Unset Press top button PA Press the two orange side buttons tog...

Page 12: ...12 of 12 496368 Issue 1 ...