Scantronic 460 Installation Instructions Download Page 2

2

DE1833

3.2 Illustrated Installation Procedure

 

    

 

  

4

44

4. SPECIAL COMMENTS

. SPECIAL COMMENTS

. SPECIAL COMMENTS

. SPECIAL COMMENTS     

4.1 Product Limitations

Although this detector is a highly reliable device, it does not
guarantee complete protection against intrusion. Even the most
sophisticated detectors can sometimes be defeated or may fail to
warn because:

A.

The detector will not function if the DC power supplied to it is
incorrect or improperly connected.

B.

A PIR detector does not provide full volumetric coverage. It can
only detect motion that disturbs the sensitive beams spread within
the protected area.  

C.

Motion is not detected if it takes place behind closed doors, walls,
glass partitions, windows and shutters.

D.

The detection ability of the PIR detector may be reduced by
malicious masking or by spraying various materials on the lens or
by mechanical tampering with the optical system.

E.

As the ambient temperature of the protected area approaches the
range of 32°C-40°C (90°F-105°F), the PIR detector's performance
can decrease.

F.

Even the most reliable electrical devices, including this detector,
may go wrong due to an unexpected failure of a component part.

The above list includes the most common reasons for failure to
detect intrusion, but it is by no means comprehensive. It is therefore
recommended that the detector and the entire alarm system be
checked weekly, to ensure proper performance.
An alarm system should not be regarded as a substitute for
insurance. Home and property owners or renters should be prudent
enough to continue insuring their lives and property, even though
they are protected by an alarm system.

1

2

4

3

6

5

Set jumpers as needed

1.8 - 2.4 m (6 - 8  ft) above ground

Open holes in base

Disassemble unit

Mount base

Walk-test the coverage area

Wire up the terminal block

Summary of Contents for 460

Page 1: ...ection Range Up to 12 m Tripping Indication Indicator lights GREEN for about 3 sec Figure 3 Maximum Coverage Pattern ALARM and TAMPER Alarm Output Solid state relay N C up to 100 mA 30 V 30 Ω internal resistance Circuit opens for 2 3 seconds upon alarm Alarm Indication Indicator lights RED for about 3 seconds Event Counter Selectable 1 or 2 motion events Tamper Contacts Normally closed 50 mA resis...

Page 2: ...r by spraying various materials on the lens or by mechanical tampering with the optical system E As the ambient temperature of the protected area approaches the range of 32 C 40 C 90 F 105 F the PIR detector s performance can decrease F Even the most reliable electrical devices including this detector may go wrong due to an unexpected failure of a component part The above list includes the most co...

Page 3: ...is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or re locate the receiving antenna Increase the distance between the device and the receiver Connect the device to an o...

Page 4: ...heldean Gloucestershire GL17 0SZ Product Support UK Tel 09068 616343 Between 09 00 and 17 30 Monday to Thursday 09 00 to 17 00 Friday CALLS CHARGED AT 60p PER MINUTE Product Support Fax 01594 545401 Internet www coopersecurity co uk 2001 SCANTRONIC 460 DE1833 REV 0 6 01 ...