10
3.4 Fixing of machine
When the machine is positioned on the right
working place, it should be fixed to 2x Ø10mm
screws and plugs (not included). Preferable is a
concrete floor to fix the press tight.
In both feet there is a holes foreseen to fix the
machine. Take over the holes position, drill the
correct hole size for the plug and fix the machine.
Fig.8 Machine fixing hole
3.5 Installation of hydraulic unit
Fig.9 Installation hydraulic unit
(bolt b)
(bolt a inside u-profile)
Tip: the hydraulic unit weights about 35kg. For placing the unit in the
correct position, foresee enough man- or machine power to lift the unit.
In transport condition the hydraulic unit is mounted in the inside the frame. To place the
unit in working position:
•
Remove the 4x M10 bolts (a) which holds the hydraulic unit to the angle brackets
•
Take out the complete unit outside the frame. Do not loosen or dismantle the
hydraulic hoses for this.
•
Remove 4x M10 bolts (b)
•
Remove the 2x angle brackets from the inside to the outside of the frame
•
Fix the brackets again with bolt (b) on the same treaded holes as before. Make sure
the brackets are placed parallel to each other and perpendicular to the frame
•
Place the hydraulic unit back on the brackets and fix it with 4x bolt (a)