![SCANMASKIN Scan Combiflex 800 User Manual Download Page 24](http://html1.mh-extra.com/html/scanmaskin/scan-combiflex-800/scan-combiflex-800_user-manual_1206751024.webp)
Scan Combiflex 800 – Manual
Chapter 3
- 20 -
Make sure the machine is in its “Safety off position”
Tilt the machine backwards and secure it.
Remove any tools used.
Loosen the three screws holding the Scan-On plate.
Replace the Scan-On plate.
It’s recommended that new screws are used to fasten the replacement Scan-On plate.
It’s also recommended that copper paste is used on the surface of the screw hole at the Scan-On
plate.
Tighten all screws by hand and make sure that they are secured.
5.5 Cleaning the machine
Before starting to clean the machine, make sure it is in its ”Safety off position”
The power must not be connected while cleaning the machine.
Do not use highly pressurized water to clean the machine.
Water and soap is recommended.
5.6 Trouble shooting
5.6.1 Common faults
Symptom
Cause
Correction
A
5
The machine won’t start
There is a power failure from the power supply
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full voltage
near the machine
O
E
E
The emergency stop button is depressed
Release the emergency stop button.
O
Internal error
If possible, read the alarm or fault code present at the display
inside of the electrical cabinet. Alarm codes are formatted as
“Axxxx” where “x” is the number. Fault codes are formatted
as “Fxxxx”.
Contact Scanmaskin Sweden AB
O
The machine is weak and
might stop when on the
ground.
One of the three phases are missing from the
power supply
There is a voltage drop at the power supply
Inspect the display on the inverter for any alarm code
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full voltage
at the cable end near the machine.
Make sure that the cable is not to long. If the cable should be
to long, use a cable with higher rating to a distribution box
nearer the machine.
O
O
E
E
O
The machine vibrates a lot
The grinding speed is to high
Lower the speed
O
The tools are damaged
Inspect the tools
Change the tools if needed
O
O
Table 5-1
Common faults
5
See access table ”Table 5-3”