Connection to electric power take-off
Work on electric power take-off (PTO EL)
Scania Truck Bodybuilder
22:10-834 Issue 2 2021-11-11
© Scania CV AB 2021, Sweden
27 (32)
IMPORTANT!
Depending on the dimension selected for the cable fitting, it may be necessary to fit
a reducer from the terminal box thread to the relevant thread on the fitting. The max-
imum thread length to the terminal box is 8 mm; see illustration.
Fit cable fittings and ring terminals to the electric power take-off as follows:
1.
Strip off the appropriate length of the outer jacket of the cable and the part of the
shield where the ring terminal will be fitted. Wind insulation tape around the end
of the shield to protect it from damage. The cable fitting seal should be around
the outer jacket of the cable and the cable fitting spring should be around the ca-
ble shield.
2.
Insert the cable into the cable grommet while rotating it slightly. Do not tighten
the pressure screw.
3.
Press the ring terminal into place in accordance with the manufacturer's instruc-
tions
4.
Fit the cable grommet in the terminal box.
5.
Tighten the pressure screw.
444 252
Reducer with seal to the terminal box.