Adjustable parameters
|
Instructions for use
|
SCANIA Interlock
®
7x00
31
10 Adjustable
parameters
Some instrument parameters may be set differently by a Dräger Interlock
service centre due to legal regulations in different countries or individually
during installation. The descriptions of these Instructions for Use are related to
the basic version.
Table of essential adjustable parameters:
11 Order
list
Ignition lead
5 V to 48 V
Waiting time to be ready for measurement
20 °C
2 s
0°C
<5 s
-25°C
<60 s
-40°C
<110 s
Parameter
Basic version
Operation
Display of test result
Test passed
/
Test failed
Breath test volume
1.0 L
Limit value (initial test)
0.30‰ or 0.20‰
Restart period
30 minutes
Data storage
Data storage
on
Service
Calibration interval
365 days
Possible to start engine after the end
of the service interval
Yes
Retest
Retests (whilst the vehicle is in use)
No
Lockouts
Duration of the instrument lockout
after a breath alcohol test with a high
concentration
5 minutes
Access code
Access code (for overriding the instru-
ment for a limited time period)
Yes
Name and description
Order no.
Dräger Interlock 7x00
Alcohol interlock (handset and control unit) for
installation in motor vehicles, 12 V to 24 V,
mouthpieces (3 pieces) and mounting accesso-
ries
83 22 570
Mouthpieces (5 pieces)
83 26 550
Mouthpieces (50 pieces)
83 27 627
Mouthpieces (300 pieces)
83 22 597
Camera
83 22 413
GPRS module (complete)
83 22 534
Cable set for connecting horn and headlights
83 22 417
Cable set for connecting horn
83 22 416
Holster for handset
83 22 497
Holster II for handset
83 22 610
Spiral cable, length 1.5 m (car)
83 15 909
Parameter
Basic version