background image

 

 

 

User Manual 

SP006PH-10G 

Introduction 

 

SP006PH-10G is an in-line surge protector designed for preventing damage to PoE (Power over Ethernet) 
devices from high voltage surges. 

 
 

Features 

 

 

Surge current up to 20KA 

 

Supports data rate up to 10Gpbs 

 

Supports Mid-Span and End-Span PoE 

 

Built-in two stage protection with GDTs and SIDACTORs 

 

Supports protection for both differential and common mode 

 

Response time less than 1ns 

 

IEC 61000-4-2, IEC61000-4-5, UL497B compliance 

 

Supports multiple mounting options (Wall/Rack mounting & Din-Rail) 

 
 

Installation view 

 
 
 
 
 
 

 

 

 

Bandwidth/ Distance   

 
For 10G application, the maximum distance is 80M. SC&T uses COMMSCOPE CAT6a cable for testing, the 
data rate may be slightly compromised by connected equipment, cables, and connectors.   

 
 
 

 

Summary of Contents for SP006PH-10G

Page 1: ...Smart Cabling Transmission Corp V1 0 Surge Protector Series User Manual Model SP006PH 10G High Performance 10G PoE Surge Protector ...

Page 2: ...n PoE Built in two stage protection with GDTs and SIDACTORs Supports protection for both differential and common mode Response time less than 1ns IEC 61000 4 2 IEC61000 4 5 UL497B compliance Supports multiple mounting options Wall Rack mounting Din Rail Installation view Bandwidth Distance For 10G application the maximum distance is 80M SC T uses COMMSCOPE CAT6a cable for testing the data rate may...

Page 3: ...Connector To connect the cable transmission side 2 GND Connection To connect the ground 3 Protected Connector To connect the device to be protected RJ45 Pin Define TIA EIA 568 B Pin Pin Color 1 Orange white 2 Orange 3 Green white 4 Blue 5 Blue white 6 Green 7 Brown white 8 Brown ...

Page 4: ... protected can prevent your PoE device from surges so we recommend using a SP006PH 10G for each of your PoE device that needs to be protected Ensure the input port connects to a network cable as below sssss To effectively protect your PoE device please ensure the product is properly grounded DO NOT connect the ground wire to power wire The ground resistance value should be less than 100Ω The prote...

Page 5: ...nt 8A Surge Discharge Current 20KA 8 20us Peak Pulse Current 200A 10 1000us Protection Mode Differential and Common Mode Insulation Resistance 10000Ω Capacitance line to line 2 5pF ESD Protection 30KV Contact Air Ports Interfaces Data Input 1 x RJ45 Data Output 1 x RJ45 Ambient Temperature Operation 40 to 70 Storage 40 to 90 Max Operating Altitude 2000m Humidity Up to 95 Physical Characteristics M...

Page 6: ...stallation Guide Accessory A Machine Screw B Self drilling Screw C Screw Plug D Angle Bracket E DIN rail Mounting Plat F 1U Rack Installed on a Platform Step 1 Use machine screws to fix angle brackets on both sides of your product ...

Page 7: ...6 User Manual SP006PH 10G Step 2 Use self drilling screws to fix the product on a platform Step 3 Move the product to get fixed and then lock the screws ...

Page 8: ...1 Same way as Installed on a Platform but need to put screw plugs into the wall before inserting the screws leave 2mm space from the platform Installed on a Din Rail Step 1 Use machine screws to fix a din rail mounting plat on the side of your product ...

Page 9: ...8 User Manual SP006PH 10G Step 2 Install your product on a DIN rail as following instruction Installed on a Rack Step 1 Lock machine screws in the rack Step 2 Put your products on the rack ...

Page 10: ...9 User Manual SP006PH 10G Step 3 Push the products to the other side of the rack Step 4 Install the rack in a cabinet ...